Lattice Membrane for Improved Mechanical Characteristics of Monolithic Flexure-Hinge Based Anthropomorphic Hands

Flexure-based mechanisms offer a promising alternative to traditional rigid-link joints in robotic hands. They enable simplified construction, reduced weight, and adaptability through their intrinsic compliance. This paper presents the design and mechanical characterization of a compound flexure-hinge joint with a lattice membrane for use in a monolithic anthropomorphic hand. A series of experimental tests were conducted to evaluate the joint's stiffness in flexion and torsion, which were compared to joints from existing literature. Additionally, its durability under cyclic loading was examined, together with the functional grasping capabilities of a full anthropomorphic hand utilizing this joint. Results demonstrate that the joint exhibits increased torsional stiffness of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{5. 5 1} \boldsymbol{\pm} \mathbf{0. 4 7 ~ N m m} /$</tex> degree compared to <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{0. 5 2} \pm 0.08 \text{Nmm} /$</tex> degree for a simple flexure-hinge joint. Additionally, it has a smooth response under flexion at a stiffness of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.50 \pm 0.07 ~\mathrm{N} / \text{mm}$</tex> compared to a full membrane which has a variable stiffness between <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.54 \pm 0.10 ~\mathrm{N} / \text{mm}$</tex> and <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$1.30 \pm 0.17 ~\mathrm{N} / \text{mm}$</tex>, caused by a buckling response. Preliminary results also showed that the joint can withstand cyclic loading without failure, but with some deformation, for over <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{3 0 0, 0 0 0}$</tex> cycles, and the ability of a hand utilizing these joints to perform essential grips for successful operation. Clear benefits to incorporating the lattice structure are presented, which include, added torsional stiffness compared to a simple flexurehinge joint, a smooth force profile compared to a full membrane. The lattice design also prevents object interference with the joint cavity during grasping. These findings support the viability of the proposed design approach for use in adaptive, lightweight and compact robotic hands, with applications in humanoid robots and upper-limb prosthetics.

Authors

Institutions

Publication Details

Published
2025-09-30
DOI
https://doi.org/10.1109/humanoids65713.2025.11203202
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lattice Membrane for Improved Mechanical Characteristics of Monolithic Flexure-Hinge Based Anthropomorphic Hands

Nicola Y. Bailey, Benjamin Metcalfe, R. E. Irving, Nicos Hadjigeorgiou et al.
Muscle activation and electromyography studies
article

Lattice Membrane for Improved Mechanical Characteristics of Monolithic Flexure-Hinge Based Anthropomorphic Hands

Nicola Y. Bailey, Benjamin Metcalfe, R. E. Irving, Nicos Hadjigeorgiou, Emmanouil Spyrakos-Papastavridis
article en

Abstract

Flexure-based mechanisms offer a promising alternative to traditional rigid-link joints in robotic hands. They enable simplified construction, reduced weight, and adaptability through their intrinsic compliance. This paper presents the design and mechanical characterization of a compound flexure-hinge joint with a lattice membrane for use in a monolithic anthropomorphic hand. A series of experimental tests were conducted to evaluate the joint's stiffness in flexion and torsion, which were compared to joints from existing literature. Additionally, its durability under cyclic loading was examined, together with the functional grasping capabilities of a full anthropomorphic hand utilizing this joint. Results demonstrate that the joint exhibits increased torsional stiffness of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{5. 5 1} \boldsymbol{\pm} \mathbf{0. 4 7 ~ N m m} /$</tex> degree compared to <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{0. 5 2} \pm 0.08 \text{Nmm} /$</tex> degree for a simple flexure-hinge joint. Additionally, it has a smooth response under flexion at a stiffness of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.50 \pm 0.07 ~\mathrm{N} / \text{mm}$</tex> compared to a full membrane which has a variable stiffness between <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.54 \pm 0.10 ~\mathrm{N} / \text{mm}$</tex> and <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$1.30 \pm 0.17 ~\mathrm{N} / \text{mm}$</tex>, caused by a buckling response. Preliminary results also showed that the joint can withstand cyclic loading without failure, but with some deformation, for over <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mathbf{3 0 0, 0 0 0}$</tex> cycles, and the ability of a hand utilizing these joints to perform essential grips for successful operation. Clear benefits to incorporating the lattice structure are presented, which include, added torsional stiffness compared to a simple flexurehinge joint, a smooth force profile compared to a full membrane. The lattice design also prevents object interference with the joint cavity during grasping. These findings support the viability of the proposed design approach for use in adaptive, lightweight and compact robotic hands, with applications in humanoid robots and upper-limb prosthetics.

King's College London (GB), University of Bath (GB)
Openalex Percentile: Top 70%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.