Carboxylated Polystyrene Particles for Plastic Standards in Laser Ablation ICP–MS Trace Elements Analysis: Analytical Aspects and Environmental Relevance

Reliable quantification of trace metals in polymers by direct solid-state analysis remains limited by the lack of suitable reference materials. In this study, we introduce a novel method for producing standardized plastic samples specifically designed for the calibration and analysis of trace metals by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Carboxylated polystyrene (PS) nanoparticles, capable of adsorbing metal ions from solution, were synthesized and evaluated. The trace metal adsorption capabilities of these PS nanoparticles were assessed with adsorption isotherms fit well with the Freundlich model. The study focused cobalt (Co<sup>2+</sup>), copper (Cu<sup>2+</sup>), and lead (Pb<sup>2+</sup>) The adsorption constants were found to be 0.15 for Co<sup>2+</sup>, 0.48 for Cu<sup>2+</sup>, and 3.63 for Pb<sup>2+</sup>. The metal-sorbed PS nanoparticles were then processed into disc-shaped plastics via hot-press molding, and LA-ICP-MS analysis confirmed the homogeneous metal distribution both at the surface and in depth, with relative standard deviations (RSD) of less than 5% for all metals analyzed. Calibration curves for Pb<sup>2+</sup> (1220-4400 mg kg<sup>-1</sup>), Cu<sup>2+</sup> (210-600 mg kg<sup>-1</sup>), and Co<sup>2+</sup> (67-220 mg kg<sup>-1</sup>) showed strong linear relationships, with <i>R</i> <sup>2</sup> values of 0.96 for Pb<sup>2+</sup>, 0.95 for Cu<sup>2+</sup>, and 0.94 for Co<sup>2+</sup>. The methodology limits of detection (LOD) were determined to be 113 mg kg<sup>-1</sup> for Pb<sup>2+</sup>, 93 mg kg<sup>-1</sup> for Cu<sup>2+</sup>, and 23 mg kg<sup>-1</sup> for Co<sup>2+</sup>. The developed standards enabled the calibration of analytical instruments and thus improve the reliability of assessments concerning the contamination of environments with metal-laden microplastics.

Authors

Institutions

Publication Details

Journal
ACS Measurement Science Au
Published
2025-10-24
DOI
https://doi.org/10.1021/acsmeasuresciau.5c00107
Citations
1
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Carboxylated Polystyrene Particles for Plastic Standards in Laser Ablation ICP–MS Trace Elements Analysis: Analytical Aspects and Environmental Relevance

Bruno Grassl, Maud Gautier, Stéphanie Reynaud, Javier Jiménez‐Lamana et al.
1 citations
ACS Measurement Science Au
Analytical chemistry methods development
0.75
article

Carboxylated Polystyrene Particles for Plastic Standards in Laser Ablation ICP–MS Trace Elements Analysis: Analytical Aspects and Environmental Relevance

Bruno Grassl, Maud Gautier, Stéphanie Reynaud, Javier Jiménez‐Lamana, Sandra Mounicou
article en
1 citations

Abstract

Reliable quantification of trace metals in polymers by direct solid-state analysis remains limited by the lack of suitable reference materials. In this study, we introduce a novel method for producing standardized plastic samples specifically designed for the calibration and analysis of trace metals by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Carboxylated polystyrene (PS) nanoparticles, capable of adsorbing metal ions from solution, were synthesized and evaluated. The trace metal adsorption capabilities of these PS nanoparticles were assessed with adsorption isotherms fit well with the Freundlich model. The study focused cobalt (Co<sup>2+</sup>), copper (Cu<sup>2+</sup>), and lead (Pb<sup>2+</sup>) The adsorption constants were found to be 0.15 for Co<sup>2+</sup>, 0.48 for Cu<sup>2+</sup>, and 3.63 for Pb<sup>2+</sup>. The metal-sorbed PS nanoparticles were then processed into disc-shaped plastics via hot-press molding, and LA-ICP-MS analysis confirmed the homogeneous metal distribution both at the surface and in depth, with relative standard deviations (RSD) of less than 5% for all metals analyzed. Calibration curves for Pb<sup>2+</sup> (1220-4400 mg kg<sup>-1</sup>), Cu<sup>2+</sup> (210-600 mg kg<sup>-1</sup>), and Co<sup>2+</sup> (67-220 mg kg<sup>-1</sup>) showed strong linear relationships, with <i>R</i> <sup>2</sup> values of 0.96 for Pb<sup>2+</sup>, 0.95 for Cu<sup>2+</sup>, and 0.94 for Co<sup>2+</sup>. The methodology limits of detection (LOD) were determined to be 113 mg kg<sup>-1</sup> for Pb<sup>2+</sup>, 93 mg kg<sup>-1</sup> for Cu<sup>2+</sup>, and 23 mg kg<sup>-1</sup> for Co<sup>2+</sup>. The developed standards enabled the calibration of analytical instruments and thus improve the reliability of assessments concerning the contamination of environments with metal-laden microplastics.

ACS Measurement Science AuVol. 5(6)
Centre National de la Recherche Scientifique (FR), Université de Pau et des Pays de l'Adour (FR), Institut des Sciences Analytiques et de Physico-Chimie pour l'Environnement et les Matériaux (FR)
Openalex Percentile: Top 25%
Analytical chemistry methods development
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.