A New Fluorescence Imaging Method to Evaluate Different Oil Types and Their Concentrations in Water

Abstract Oil pollution in aquatic systems remains a major global issue, especially due to bilge water discharges that may exceed the 15 ppm oil‐in‐water (OiW) threshold set by the International Maritime Organization (IMO). In this study, an improved fluorescence imaging method is presented for quantifying oil concentration and simultaneously characterizing droplet distributions in dynamic emulsions. OiW emulsions of four different oil types were prepared without chemical stabilizers in a range from 5 to 100 ppm. The images were processed with custom algorithms to determine fluorescence signal, droplet number, and size distribution. The calibration showed a strong linear correlation between fluorescence and oil concentration ( R 2 = 0.967–0.999).

Authors

Institutions

Publication Details

Journal
Chemical Engineering & Technology
Published
2025-10-01
DOI
https://doi.org/10.1002/ceat.70128
Primary Topic
Oil Spill Detection and Mitigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A New Fluorescence Imaging Method to Evaluate Different Oil Types and Their Concentrations in Water

Katharina Zähringer, Thomas Hagemeier, Daniel Müller, Jessica Dafis
Chemical Engineering & Technology
Oil Spill Detection and Mitigation
article

A New Fluorescence Imaging Method to Evaluate Different Oil Types and Their Concentrations in Water

Katharina Zähringer, Thomas Hagemeier, Daniel Müller, Jessica Dafis
article en

Abstract

Abstract Oil pollution in aquatic systems remains a major global issue, especially due to bilge water discharges that may exceed the 15 ppm oil‐in‐water (OiW) threshold set by the International Maritime Organization (IMO). In this study, an improved fluorescence imaging method is presented for quantifying oil concentration and simultaneously characterizing droplet distributions in dynamic emulsions. OiW emulsions of four different oil types were prepared without chemical stabilizers in a range from 5 to 100 ppm. The images were processed with custom algorithms to determine fluorescence signal, droplet number, and size distribution. The calibration showed a strong linear correlation between fluorescence and oil concentration ( R 2 = 0.967–0.999).

Chemical Engineering & TechnologyVol. 48(10)
Waldkrankenhaus Rudolf Elle (DE), Otto-von-Guericke-Universität Magdeburg (DE)
Openalex Percentile: Top 76%
Oil Spill Detection and Mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.