A comparative investigation of the quality of radiographs produced by portable handheld and fixed x-ray units
To evaluate the impact of handheld portable intraoral diagnostic X-ray equipment on radiographic quality and to compare their radiographs with radiographs obtained using fixed intraoral X-ray equipment. For brightness, noise, and uniformity, radiographs of an acrylic block were obtained with two complementary metal oxide semiconductor (CMOS) sensors (Digora Toto and Snapshot). Six radiographs for each sensor were obtained using the Eagle handheld portable X-ray equipment set at 60 kVp, 2.5 mA, and 0.45 s. Then, six radiographs were obtained with the Focus fixed X-ray equipment set at 60 kVp, 7 mA, and 0.16 s. Mean and standard deviation of the gray values were evaluated. For contrast, radiographs of an aluminum step-wedge were obtained using both sensors, X-ray equipment, and the aforementioned acquisition parameters. The percentage of contrast variation was evaluated. The comparison between the equipment was evaluated for its influence on radiographic quality using Student's t-test (p < 0.05). The handheld portable X-ray equipment produced radiographs with higher brightness and lower contrast regardless of the CMOS sensor used (p<0.0001). Noise levels were higher with the handheld portable X-ray equipment than with the fixed X-ray equipment using the Digora Toto system, and lower with the Snapshot system (p < 0.05). No significant differences were found for uniformity. Therefore, radiographs obtained with a handheld portable intraoral diagnostic X-ray equipment have higher brightness and lower contrast compared to those obtained with fixed X-ray equipment. While the effect on noise levels varies depending on the digital system used, the uniformity remains unaffected by the type of X-ray equipment.
Authors
- Rocharles Cavalcante Fontenele (ORCID: https://orcid.org/0000-0002-6426-9768)
- Deborah Queiroz Freitas (ORCID: https://orcid.org/0000-0002-1425-5966)
- Débora Costa Ruiz (ORCID: https://orcid.org/0000-0002-2223-1286)
- Matheus L. Oliveira (ORCID: https://orcid.org/0000-0002-8054-8759)
- Francisco Haiter‐Neto (ORCID: https://orcid.org/0000-0002-5610-8307)
Institutions
- Universidade Estadual de Campinas (UNICAMP) (BR)
Publication Details
- Journal
- Brazilian Dental Journal
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1590/0103-644020256319
- Primary Topic
- Dental Radiography and Imaging
- Type
- article
- Field-Weighted Citation Impact
- 0.00