Role of tube current variation and metal artifact reduction tool in CBCT for detection of missing MB2 canal

We aimed to evaluate the effect of varying the tube current and the Metal Artifact Reduction (MAR) tool on the detection of the missing second mesiobuccal (MB2) canal. Forty maxillary molars (20 with and 20 without MB2) were selected and confirmed by micro-CT. The teeth underwent endodontic preparation, with the canals filled using gutta-percha and a silver-palladium metal post. CBCT scans were acquired using the OP300 Maxio system (voxel size: 0.085 mm, FOV: 50 x 50 mm) at 4 mA, 6.3 mA, and 12.5 mA, with and without MAR activation. The areas under the receiver operating characteristic curves (AUCs), sensitivities, and specificities were calculated for five examiners and compared using two-way ANOVA (p < 0.05). Intra- and interexaminer agreements were assessed using the weighted Kappa test. The AUC values ranged from 0.90 to 0.94, sensitivity from 0.75 to 0.78, and specificity from 0.89 to 0.95. Intra- and interexaminer indices ranged from moderate to substancial. Based on the tube current settings or MAR activation, there were no significant differences in the MB2 canal detection. Therefore, varying the tube current and MAR tool activation did not affect MB2 canal detection, with values close to 4 mA without MAR activation recommended in this scenario to reflect a better dose-benefit ratio.

Authors

Institutions

Publication Details

Journal
Brazilian Dental Journal
Published
2025-01-01
DOI
https://doi.org/10.1590/0103-644020256491
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Role of tube current variation and metal artifact reduction tool in CBCT for detection of missing MB2 canal

Deborah Queiroz Freitas, Fernanda Bulhões Fagundes, Frederico Sampaio Neves, Lucas P. Lopes Rosado et al.
Brazilian Dental Journal
Medical Imaging Techniques and Applications
article

Role of tube current variation and metal artifact reduction tool in CBCT for detection of missing MB2 canal

Deborah Queiroz Freitas, Fernanda Bulhões Fagundes, Frederico Sampaio Neves, Lucas P. Lopes Rosado, Caio Alencar‐Palha, Marcyele Natane da Silva Morais
article en

Abstract

We aimed to evaluate the effect of varying the tube current and the Metal Artifact Reduction (MAR) tool on the detection of the missing second mesiobuccal (MB2) canal. Forty maxillary molars (20 with and 20 without MB2) were selected and confirmed by micro-CT. The teeth underwent endodontic preparation, with the canals filled using gutta-percha and a silver-palladium metal post. CBCT scans were acquired using the OP300 Maxio system (voxel size: 0.085 mm, FOV: 50 x 50 mm) at 4 mA, 6.3 mA, and 12.5 mA, with and without MAR activation. The areas under the receiver operating characteristic curves (AUCs), sensitivities, and specificities were calculated for five examiners and compared using two-way ANOVA (p < 0.05). Intra- and interexaminer agreements were assessed using the weighted Kappa test. The AUC values ranged from 0.90 to 0.94, sensitivity from 0.75 to 0.78, and specificity from 0.89 to 0.95. Intra- and interexaminer indices ranged from moderate to substancial. Based on the tube current settings or MAR activation, there were no significant differences in the MB2 canal detection. Therefore, varying the tube current and MAR tool activation did not affect MB2 canal detection, with values close to 4 mA without MAR activation recommended in this scenario to reflect a better dose-benefit ratio.

Brazilian Dental JournalVol. 36
Universidade Federal da Bahia (BR), Universidade Estadual de Campinas (UNICAMP) (BR), Universidade Federal do Espírito Santo (BR)
Openalex Percentile: Top 55%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Role of tube current variation and metal artifact reduction tool in CBCT for detection of missing MB2 canal — Deborah Queiroz Freitas, Fernanda Bulhões Fagundes, et al. · Brazilian Dental Journal (2025) | TGRS Research Map | TGRS