Automatic milking and incidence of mastisis in cows

One of the main aspects of obtaining milk of high sanitary quality is functioning of milking equipment. Currently, the main volume of dairy products produced comes from dairy complexes equipped with milking parlors with automatic milking system. However, as practice shows, in the automatic milking system, settings may fail and be incorrectly set, leading to negative effect on mammary gland of cows. Hence, the goal of the research was to study the effect of settings of automatic milking equipment (vacuum in teat chamber, minimum milk flow when removing milking machines) on functional state of mammary gland of high-yielding lactating cows. The experiments were carried out in two milking parlors. At milking parlor 1, there was no maintenance of milking machine for three years. At milking parlor 2, there was regular maintenance with testing of each milking machine. It was established that with regular maintenance (milking parlor 2), the milking vacuum was in the range of 3739 kPa, in the main pipe - 4042 kPa, i. e. the difference was no more than 2-3 kPa. Insufficient vacuum in teat chamber (3436 kPa) resulted in 1.6-2.0-fold increase in duration of milking, 2.5-4.0-fold increase in number of cows with udder irritation, 3.0-4.2-fold increase in incidence of subclinical mastitis, 3.2-11.8-fold increase in incidence of clinical mastitis, 2.0-3.2-fold increase in number of somatic cells in collected milk. Increase in minimum milk flow up to 450500 g/min after turning off the milking machine ensures 3.9-fold reduction in the number of cows with udder irritation, 4.1-fold reduction of cows with subclinical mastitis, 21.2-fold reduction of cows with clinical mastitis, and 4.2-fold decrease in the number of somatic cells in collected milk (145.5 thousand/ml that corresponds to premium milk).

Authors

Institutions

Publication Details

Journal
RUDN Journal of Agronomy and Animal Industries
Published
2024-12-15
DOI
https://doi.org/10.22363/2312-797x-2024-19-3-507-516
Primary Topic
Milk Quality and Mastitis in Dairy Cows
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automatic milking and incidence of mastisis in cows

В.И. Михалев, В.И. Зимников
RUDN Journal of Agronomy and Animal Industries
Milk Quality and Mastitis in Dairy Cows
article

Automatic milking and incidence of mastisis in cows

В.И. Михалев, В.И. Зимников
article en

Abstract

One of the main aspects of obtaining milk of high sanitary quality is functioning of milking equipment. Currently, the main volume of dairy products produced comes from dairy complexes equipped with milking parlors with automatic milking system. However, as practice shows, in the automatic milking system, settings may fail and be incorrectly set, leading to negative effect on mammary gland of cows. Hence, the goal of the research was to study the effect of settings of automatic milking equipment (vacuum in teat chamber, minimum milk flow when removing milking machines) on functional state of mammary gland of high-yielding lactating cows. The experiments were carried out in two milking parlors. At milking parlor 1, there was no maintenance of milking machine for three years. At milking parlor 2, there was regular maintenance with testing of each milking machine. It was established that with regular maintenance (milking parlor 2), the milking vacuum was in the range of 3739 kPa, in the main pipe - 4042 kPa, i. e. the difference was no more than 2-3 kPa. Insufficient vacuum in teat chamber (3436 kPa) resulted in 1.6-2.0-fold increase in duration of milking, 2.5-4.0-fold increase in number of cows with udder irritation, 3.0-4.2-fold increase in incidence of subclinical mastitis, 3.2-11.8-fold increase in incidence of clinical mastitis, 2.0-3.2-fold increase in number of somatic cells in collected milk. Increase in minimum milk flow up to 450500 g/min after turning off the milking machine ensures 3.9-fold reduction in the number of cows with udder irritation, 4.1-fold reduction of cows with subclinical mastitis, 21.2-fold reduction of cows with clinical mastitis, and 4.2-fold decrease in the number of somatic cells in collected milk (145.5 thousand/ml that corresponds to premium milk).

RUDN Journal of Agronomy and Animal IndustriesVol. 19(3)
All-Russian Scientific Research Veterinary Institute of Pathology, Pharmacology and Therapy (RU)
Openalex Percentile: Top 58%
Milk Quality and Mastitis in Dairy Cows
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.