Direct Measurement of QED Radiative Effects in PRad Experiment

The PRad experiment at Jefferson Lab has precisely measured the cross sections for elastic electron-proton scattering at four momentum transfer square $2\times 10^{-4} < Q^2 < 6\times 10^{-2}$ GeV$^2$. The proton's charge radius was extracted based on the measured proton form factors at very low $Q^2$. This experiment utilized a high-precision, hybrid calorimeter (HyCal) to precisely determine the energy and position of electrons and photons. The HyCal's inner array of PbWO$_4$ modules can well separate two incident particles with a distance greater than about 30 mm (of the module size) on the detection plane. Together with the GEM detectors placed in front of the HyCal, which serve as a veto detector for neutral particles, the PRad detector system is capable of measuring and identifying the scattered electrons and the radiative photons simultaneously from the elastic $ep$ and $ee$ scattering processes. In this proceeding, the preliminary results of the direct radiative effects measurement from the PRad experiment are discussed; the expected improvements with the upcoming PRad-II experiment are also presented.

Authors

Publication Details

Published
2025-10-24
DOI
https://doi.org/10.22323/1.483.0072
Primary Topic
Optical Systems and Laser Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct Measurement of QED Radiative Effects in PRad Experiment

D. Dutta, Chao Peng
Optical Systems and Laser Technology
article

Direct Measurement of QED Radiative Effects in PRad Experiment

D. Dutta, Chao Peng
article en

Abstract

The PRad experiment at Jefferson Lab has precisely measured the cross sections for elastic electron-proton scattering at four momentum transfer square $2\times 10^{-4} < Q^2 < 6\times 10^{-2}$ GeV$^2$. The proton's charge radius was extracted based on the measured proton form factors at very low $Q^2$. This experiment utilized a high-precision, hybrid calorimeter (HyCal) to precisely determine the energy and position of electrons and photons. The HyCal's inner array of PbWO$_4$ modules can well separate two incident particles with a distance greater than about 30 mm (of the module size) on the detection plane. Together with the GEM detectors placed in front of the HyCal, which serve as a veto detector for neutral particles, the PRad detector system is capable of measuring and identifying the scattered electrons and the radiative photons simultaneously from the elastic $ep$ and $ee$ scattering processes. In this proceeding, the preliminary results of the direct radiative effects measurement from the PRad experiment are discussed; the expected improvements with the upcoming PRad-II experiment are also presented.

Openalex Percentile: Top 70%
Optical Systems and Laser Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.