INFLUENCE OF SMOKE CONCENTRATION AND FALSE FACTORS ON THE ACTIVATION OF AUTOMATIC FIRE ALARMS

A pressing challenge in ensuring the safety of buildings and structures is the development of reliable and efficient fire alarm systems. Despite the widespread use of various automatic fire alarm systems, many sensors exhibit high sensitivity to non-target factors such as dust, humidity, and lighting, leading to false alarms. Contemporary research often employs generalized approaches to smoke detection but typically does not account for the dynamic features of smoke propagation and the influence of external interferences. As a result, the quantitative relationship between smoke concentration, false factors, and automatic fire alarm systems response time remains unresolved. The aim of this study is to develop a mathematical model describing this relationship and an algorithm that enhances the accuracy and reliability of sensor activation. A mathematical model has been developed to describe convection and diffusion processes of smoke in an enclosed space, as well as the influence of external factors on the sensor signal. Equations are provided for calculating aerosol concentration, and a mathematical signal model is presented that incorporates the impact of false factors and smoke concentration. A smoke detection algorithm was developed to predict sensor activation time and estimate the probability of false alarms. The proposed mathematical model of the sensor signal, which accounts for smoke concentration and false factors, along with the smoke detection algorithm, can be used to calibrate the sensitivity of fire detectors, improve the accuracy of smoke detection, and reduce the number of false alarms.

Authors

Institutions

Publication Details

Journal
Scientific and analytical journal «Vestnik Saint-Petersburg university of State fire service of EMERCOM of Russia»
Published
2025-09-30
DOI
https://doi.org/10.61260/2218-130x-2025-3-1-12
Primary Topic
Fire Detection and Safety Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

INFLUENCE OF SMOKE CONCENTRATION AND FALSE FACTORS ON THE ACTIVATION OF AUTOMATIC FIRE ALARMS

А. В. Пермяков, Ildar F. Khafizov, Elina Rahmatullina, Ф.Ш. Хафизов
Scientific and analytical journal «Vestnik Saint-Petersburg university of State fire service of EMERCOM of Russia»
Fire Detection and Safety Systems
article

INFLUENCE OF SMOKE CONCENTRATION AND FALSE FACTORS ON THE ACTIVATION OF AUTOMATIC FIRE ALARMS

А. В. Пермяков, Ildar F. Khafizov, Elina Rahmatullina, Ф.Ш. Хафизов
article en

Abstract

A pressing challenge in ensuring the safety of buildings and structures is the development of reliable and efficient fire alarm systems. Despite the widespread use of various automatic fire alarm systems, many sensors exhibit high sensitivity to non-target factors such as dust, humidity, and lighting, leading to false alarms. Contemporary research often employs generalized approaches to smoke detection but typically does not account for the dynamic features of smoke propagation and the influence of external interferences. As a result, the quantitative relationship between smoke concentration, false factors, and automatic fire alarm systems response time remains unresolved. The aim of this study is to develop a mathematical model describing this relationship and an algorithm that enhances the accuracy and reliability of sensor activation. A mathematical model has been developed to describe convection and diffusion processes of smoke in an enclosed space, as well as the influence of external factors on the sensor signal. Equations are provided for calculating aerosol concentration, and a mathematical signal model is presented that incorporates the impact of false factors and smoke concentration. A smoke detection algorithm was developed to predict sensor activation time and estimate the probability of false alarms. The proposed mathematical model of the sensor signal, which accounts for smoke concentration and false factors, along with the smoke detection algorithm, can be used to calibrate the sensitivity of fire detectors, improve the accuracy of smoke detection, and reduce the number of false alarms.

Scientific and analytical journal «Vestnik Saint-Petersburg university of State fire service of EMERCOM of Russia»Vol. 2025(3)
Ufa State Petroleum Technological University (RU)
Openalex Percentile: Top 62%
Fire Detection and Safety Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

INFLUENCE OF SMOKE CONCENTRATION AND FALSE FACTORS ON THE ACTIVATION OF AUTOMATIC FIRE ALARMS — А. В. Пермяков, Ildar F. Khafizov, et al. · Scientific and analytical journal «Vestnik Saint-Petersburg university of State fire service of EMERCOM of Russia» (2025) | TGRS Research Map | TGRS