A Systematic Approach on Calibration Reference Electrode to Reversible Hydrogen Electrode Scale

Abstract The accuracy of the reference electrode potential is critical in electrochemical studies. This work studies the approach to calibrate reference electrodes experimentally to the reversible hydrogen electrode (RHE) scale in an acidic condition. Multiple working electrodes are used while varying rotation rates, scan ranges, and scan rates to demonstrate how the calibration process will affect the calibrated RHE values of reference electrodes. It is recommended to rotate the working electrode for RHE scale calibration. The cyclic voltammetry potential range is suggested to be within ±0.01 V from 0 V versus RHE to minimize errors in the analysis. The scan rate of cyclic voltammetry for RHE scale calibration is no more than 10 mV/s. This experimental practice aims to benefit the standardization of experimental reference electrode calibration in the electrochemical field.

Authors

Institutions

Publication Details

Journal
Journal of Electrochemical Energy Conversion and Storage
Published
2025-10-24
DOI
https://doi.org/10.1115/1.4070257
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Systematic Approach on Calibration Reference Electrode to Reversible Hydrogen Electrode Scale

Keith Bethune, Yunfeng Zhai, Jing Qi
1 citations
Journal of Electrochemical Energy Conversion and Storage
Analytical Chemistry and Sensors
0.74
article

A Systematic Approach on Calibration Reference Electrode to Reversible Hydrogen Electrode Scale

Keith Bethune, Yunfeng Zhai, Jing Qi
article en
1 citations

Abstract

Abstract The accuracy of the reference electrode potential is critical in electrochemical studies. This work studies the approach to calibrate reference electrodes experimentally to the reversible hydrogen electrode (RHE) scale in an acidic condition. Multiple working electrodes are used while varying rotation rates, scan ranges, and scan rates to demonstrate how the calibration process will affect the calibrated RHE values of reference electrodes. It is recommended to rotate the working electrode for RHE scale calibration. The cyclic voltammetry potential range is suggested to be within ±0.01 V from 0 V versus RHE to minimize errors in the analysis. The scan rate of cyclic voltammetry for RHE scale calibration is no more than 10 mV/s. This experimental practice aims to benefit the standardization of experimental reference electrode calibration in the electrochemical field.

Journal of Electrochemical Energy Conversion and StorageVol. 23(1)
University of Hawaiʻi at Mānoa (US), East–West Center (US)
Openalex Percentile: Top 25%
Analytical Chemistry and Sensors
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Systematic Approach on Calibration Reference Electrode to Reversible Hydrogen Electrode Scale — Keith Bethune, Yunfeng Zhai, et al. · Journal of Electrochemical Energy Conversion and Storage (2025) | TGRS Research Map | TGRS