Development of a multi-source blue light irradiation platform for photometric quantification of ascorbic acid <i>via</i> continuous absorbance quenching of the ferric–thiocyanate complex

A novel and meticulously optimised continuous flow injection analysis (CFIA) protocol was developed for the spectrophotometric quantification of ascorbic acid using a locally engineered optical system. The detection unit incorporated eight blue light-emitting diodes (LEDs) arranged in a matrix geometry distributed across two angular regions: 0-90° and 0-180°, while dual solar cells served as photonic detectors. Spectral measurements were specifically conducted at 0-180°, yielding enhanced absorbance stability and signal quality. Based on a redox-induced quenching mechanism, the system utilises a chromogenic FeSCN<sup>2+</sup> complex, formed <i>in situ</i> through the controlled mixing of ferric (Fe<sup>3+</sup>) and thiocyanate (SCN<sup>-</sup>) ions under strictly maintained physical and chemical conditions. Upon interaction at the Y-point junction, injected ascorbic acid reduces the complex, yielding a quantifiable decrease in absorbance intensity proportional to its concentration. A linear calibration range was established from 0.5 to 40 mmol L<sup>-1</sup> (<i>r</i> <sup>2</sup> = 0.9986), LOD of 0.05 mmol L<sup>-1</sup> (1.3209 μg per sample) (S/N = 3) and LOQ of 0.131 mmol L<sup>-1</sup> (S/N = 10). Method precision was evaluated at two concentrations, 12 and 30 mmol L<sup>-1</sup>, showing intra-day RSD% < 1% and inter-day RSD% < 2%, affirming excellent repeatability and method reliability. Validation was extended to three commercial pharmaceutical preparations containing 500 mg of ascorbic acid using the standard addition method. Comparative assessment against UV spectrophotometry and HPLC, with statistical evaluation <i>via</i> Student's <i>t</i>-test and one-way ANOVA, confirming no significant differences among techniques (<i>t</i>_cal < <i>t</i>_tab; <i>F</i>_cal < <i>F</i>_tab, <i>α</i> = 0.05), with recovery values between 97.13% and 103.6%.

Authors

Institutions

Publication Details

Journal
RSC Advances
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ra07160g
Citations
3
Primary Topic
Vitamin C and Antioxidants Research
Type
article
Field-Weighted Citation Impact
3.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of a multi-source blue light irradiation platform for photometric quantification of ascorbic acid via continuous absorbance quenching of the ferric–thiocyanate complex

Nagham S. Turkey, Ghufran khalid Allawi
3 citations
RSC Advances
Vitamin C and Antioxidants Research
3.36
article

Development of a multi-source blue light irradiation platform for photometric quantification of ascorbic acid via continuous absorbance quenching of the ferric–thiocyanate complex

Nagham S. Turkey, Ghufran khalid Allawi
article en
3 citations

Abstract

A novel and meticulously optimised continuous flow injection analysis (CFIA) protocol was developed for the spectrophotometric quantification of ascorbic acid using a locally engineered optical system. The detection unit incorporated eight blue light-emitting diodes (LEDs) arranged in a matrix geometry distributed across two angular regions: 0-90° and 0-180°, while dual solar cells served as photonic detectors. Spectral measurements were specifically conducted at 0-180°, yielding enhanced absorbance stability and signal quality. Based on a redox-induced quenching mechanism, the system utilises a chromogenic FeSCN<sup>2+</sup> complex, formed <i>in situ</i> through the controlled mixing of ferric (Fe<sup>3+</sup>) and thiocyanate (SCN<sup>-</sup>) ions under strictly maintained physical and chemical conditions. Upon interaction at the Y-point junction, injected ascorbic acid reduces the complex, yielding a quantifiable decrease in absorbance intensity proportional to its concentration. A linear calibration range was established from 0.5 to 40 mmol L<sup>-1</sup> (<i>r</i> <sup>2</sup> = 0.9986), LOD of 0.05 mmol L<sup>-1</sup> (1.3209 μg per sample) (S/N = 3) and LOQ of 0.131 mmol L<sup>-1</sup> (S/N = 10). Method precision was evaluated at two concentrations, 12 and 30 mmol L<sup>-1</sup>, showing intra-day RSD% < 1% and inter-day RSD% < 2%, affirming excellent repeatability and method reliability. Validation was extended to three commercial pharmaceutical preparations containing 500 mg of ascorbic acid using the standard addition method. Comparative assessment against UV spectrophotometry and HPLC, with statistical evaluation <i>via</i> Student's <i>t</i>-test and one-way ANOVA, confirming no significant differences among techniques (<i>t</i>_cal < <i>t</i>_tab; <i>F</i>_cal < <i>F</i>_tab, <i>α</i> = 0.05), with recovery values between 97.13% and 103.6%.

RSC AdvancesVol. 15(48)
University of Baghdad (IQ), Ministry of Higher Education and Scientific Research (IQ)
Openalex Percentile: Top 7%
Vitamin C and Antioxidants Research
3.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.