New Mode for 4 mm Path Irradiation and One Side Detection at 0–180° for Cu (II)ion Determination in Different Samples using On-Line Continuous Flow Feed and Simplified, Sensitive, and Portable Photometer

This study presents a rapid, sensitive, and straightforward approach for measuring Cu(II) ions using turbidity continuous flow injection analysis (CFIA) . The method involves reacting Cu(II) ion with calcium Ferro cyanide to produce a brown-red precipitate. To detect the attenuation of incident light as a result of collision on the surfaces of the precipitate particles, the analyzer NAG-SSP-5S-1D was used to measure turbidity at an angle (0–180°). The linear range of Cu(II) measurements extends from 0.01 to 5 mmol.L–1 with Correlation Coefficient of 0.9993 and R2 % = 99.86 .The limit of detection (LOD) was determined to be 23.829 ng/sample from diluted the lowest concentration in the calibration curve, and the repeatability of the method (RSD%) was demonstrated to be less than 0.3 % (n = 6) for the selected concentration (1,5 mmol.L–1). The method was successfully applied to the determination of Cu (II) ions in a variety of alloys using the standard addition method. A comparison was made between the newly developed method analysis and the classical method ((UV Spectrophotometry, λmax = 520 nm ) using t-test. It was noticed that there was no significant difference between the two methods at 95 % confidence level. Overall, the developed flow injection method offers simplicity, sensitivity, and reliable analytical performance for the determination of Cu(II) ion . Therefore the newly developed method can be used of as an alternative and an acceptable method for the analysis of Cu (II) ions in alloys compared to the reference method.

Authors

Publication Details

Journal
Baghdad Science Journal
Published
2025-10-23
DOI
https://doi.org/10.21123/2411-7986.5073
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New Mode for 4 mm Path Irradiation and One Side Detection at 0–180° for Cu (II)ion Determination in Different Samples using On-Line Continuous Flow Feed and Simplified, Sensitive, and Portable Photometer

Nagham S. Turkey Al-Awadie, Asma A. Gayed Al-Ani
Baghdad Science Journal
Analytical chemistry methods development
article

New Mode for 4 mm Path Irradiation and One Side Detection at 0–180° for Cu (II)ion Determination in Different Samples using On-Line Continuous Flow Feed and Simplified, Sensitive, and Portable Photometer

Nagham S. Turkey Al-Awadie, Asma A. Gayed Al-Ani
article en

Abstract

This study presents a rapid, sensitive, and straightforward approach for measuring Cu(II) ions using turbidity continuous flow injection analysis (CFIA) . The method involves reacting Cu(II) ion with calcium Ferro cyanide to produce a brown-red precipitate. To detect the attenuation of incident light as a result of collision on the surfaces of the precipitate particles, the analyzer NAG-SSP-5S-1D was used to measure turbidity at an angle (0–180°). The linear range of Cu(II) measurements extends from 0.01 to 5 mmol.L–1 with Correlation Coefficient of 0.9993 and R2 % = 99.86 .The limit of detection (LOD) was determined to be 23.829 ng/sample from diluted the lowest concentration in the calibration curve, and the repeatability of the method (RSD%) was demonstrated to be less than 0.3 % (n = 6) for the selected concentration (1,5 mmol.L–1). The method was successfully applied to the determination of Cu (II) ions in a variety of alloys using the standard addition method. A comparison was made between the newly developed method analysis and the classical method ((UV Spectrophotometry, λmax = 520 nm ) using t-test. It was noticed that there was no significant difference between the two methods at 95 % confidence level. Overall, the developed flow injection method offers simplicity, sensitivity, and reliable analytical performance for the determination of Cu(II) ion . Therefore the newly developed method can be used of as an alternative and an acceptable method for the analysis of Cu (II) ions in alloys compared to the reference method.

Baghdad Science JournalVol. 22(10)
Openalex Percentile: Top 65%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.