Classroom indoor air quality and its association with sick Building syndrome (SBS) symptoms in a Malaysian university setting

This study aimed to investigate the association between indoor air quality (IAQ) parameters and the prevalence of Sick Building Syndrome (SBS) symptoms among university students in different types of classrooms. The research responds to growing concerns about environmental health risks in educational settings and seeks to identify key IAQ predictors of SBS symptoms. A cross-sectional study was conducted among 205 students at a Malaysian public university. An online questionnaire adapted from the Indoor Air Quality Industry Code of Practice (ICOP-IAQ) 2010 was used to assess SBS symptoms. Simultaneously, IAQ monitoring was carried out in selected lecture halls (LHs) and tutorial rooms (TRs) using calibrated instruments to measure PM<sub>2.5</sub>, PM<sub>10</sub>, temperature, relative humidity, carbon monoxide (CO), carbon dioxide (CO<sub>2</sub>), total bacterial count, and fungal count. Comparisons were made between the classrooms. Significant differences were observed between LHs and TRs for PM<sub>2.5</sub>, PM<sub>10</sub>, temperature, relative humidity, CO, and bacterial counts. SBS symptoms were more prevalent in LHs (70.2%) than in TRs (56.6%). In LHs, CO, PM<sub>10</sub>, relative humidity, and fungal count were significantly associated with SBS symptoms, while in TRs, only CO<sub>2</sub> showed a significant association. Multivariate analysis identified CO, PM<sub>10</sub>, and fungal count as significant predictors in LHs (AOR = 4.7; p < 0.001), and CO<sub>2</sub> in TRs (AOR = 2.7; p = 0.003). IAQ parameters are significant contributors to SBS symptom prevalence among university students, with differences influenced by classroom type and ventilation design. These findings emphasize the urgency of IAQ interventions in academic institutions.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-24
DOI
https://doi.org/10.1038/s41598-025-21013-6
Citations
2
Primary Topic
Air Quality and Health Impacts
Type
article
Field-Weighted Citation Impact
2.40
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Classroom indoor air quality and its association with sick Building syndrome (SBS) symptoms in a Malaysian university setting

Nur Faseeha Suhaimi, Nurul Asyikin Mohamed Radzi, Khairun Nisaa Tamran
2 citations
Scientific Reports
Air Quality and Health Impacts
2.40
article

Classroom indoor air quality and its association with sick Building syndrome (SBS) symptoms in a Malaysian university setting

Nur Faseeha Suhaimi, Nurul Asyikin Mohamed Radzi, Khairun Nisaa Tamran
article en
2 citations

Abstract

This study aimed to investigate the association between indoor air quality (IAQ) parameters and the prevalence of Sick Building Syndrome (SBS) symptoms among university students in different types of classrooms. The research responds to growing concerns about environmental health risks in educational settings and seeks to identify key IAQ predictors of SBS symptoms. A cross-sectional study was conducted among 205 students at a Malaysian public university. An online questionnaire adapted from the Indoor Air Quality Industry Code of Practice (ICOP-IAQ) 2010 was used to assess SBS symptoms. Simultaneously, IAQ monitoring was carried out in selected lecture halls (LHs) and tutorial rooms (TRs) using calibrated instruments to measure PM<sub>2.5</sub>, PM<sub>10</sub>, temperature, relative humidity, carbon monoxide (CO), carbon dioxide (CO<sub>2</sub>), total bacterial count, and fungal count. Comparisons were made between the classrooms. Significant differences were observed between LHs and TRs for PM<sub>2.5</sub>, PM<sub>10</sub>, temperature, relative humidity, CO, and bacterial counts. SBS symptoms were more prevalent in LHs (70.2%) than in TRs (56.6%). In LHs, CO, PM<sub>10</sub>, relative humidity, and fungal count were significantly associated with SBS symptoms, while in TRs, only CO<sub>2</sub> showed a significant association. Multivariate analysis identified CO, PM<sub>10</sub>, and fungal count as significant predictors in LHs (AOR = 4.7; p < 0.001), and CO<sub>2</sub> in TRs (AOR = 2.7; p = 0.003). IAQ parameters are significant contributors to SBS symptom prevalence among university students, with differences influenced by classroom type and ventilation design. These findings emphasize the urgency of IAQ interventions in academic institutions.

Scientific ReportsVol. 15(1)
Universiti Putra Malaysia (MY)
Openalex Percentile: Top 10%
Air Quality and Health Impacts
2.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Classroom indoor air quality and its association with sick Building syndrome (SBS) symptoms in a Malaysian university setting — Nur Faseeha Suhaimi, Nurul Asyikin Mohamed Radzi, et al. · Scientific Reports (2025) | TGRS Research Map | TGRS