Abstract This pilot study aimed to establish end-to-end stereotactic radiosurgery (SRS) sessions and evaluate the accuracy of the delivered doses using EPR/alanine and GAFChromic™ EBT3 films. Six Planning Treatment Volumes (PTVs), representing variations in tumor size, location, and proximity to Organs at Risk (OARs), were assessed using an anthropomorphic male head phantom irradiated with a TomoTherapy Hi-Art system (fraction of 10.5 Gy). Maximum deviations ranged from − 0.35 to 0.16 Gy, and − 0.35 to − 0.08 Gy, for alanine and films, respectively, even under complex spatial dose distribution (e.g., PTV6). Therefore, the findings demonstrated the reliability of both systems for precise SRS dosimetry.

Authors

Institutions

Publication Details

Journal
Journal of Radioanalytical and Nuclear Chemistry
Published
2025-10-01
DOI
https://doi.org/10.1007/s10967-025-10429-z
Citations
1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.88

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetric evaluation using EPR/alanine and radiochromic film detectors in end-to-end brain stereotactic radiosurgery sessions

Alvaro de Farias Soares, Salvatore Gallo, Teresa Cucchiara, Maurizio Marrale et al.
1 citations
Journal of Radioanalytical and Nuclear Chemistry
Advanced Radiotherapy Techniques
1.88
article

Dosimetric evaluation using EPR/alanine and radiochromic film detectors in end-to-end brain stereotactic radiosurgery sessions

Alvaro de Farias Soares, Salvatore Gallo, Teresa Cucchiara, Maurizio Marrale, S. Panzeca, Giuseppina Iacoviello, Maria Cristina D’Oca, Mattia Romeo
article en
1 citations

Abstract

Abstract This pilot study aimed to establish end-to-end stereotactic radiosurgery (SRS) sessions and evaluate the accuracy of the delivered doses using EPR/alanine and GAFChromic™ EBT3 films. Six Planning Treatment Volumes (PTVs), representing variations in tumor size, location, and proximity to Organs at Risk (OARs), were assessed using an anthropomorphic male head phantom irradiated with a TomoTherapy Hi-Art system (fraction of 10.5 Gy). Maximum deviations ranged from − 0.35 to 0.16 Gy, and − 0.35 to − 0.08 Gy, for alanine and films, respectively, even under complex spatial dose distribution (e.g., PTV6). Therefore, the findings demonstrated the reliability of both systems for precise SRS dosimetry.

Journal of Radioanalytical and Nuclear ChemistryVol. 334(10)
University of Catania (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Catania (IT), Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud (IT), Osservatorio Astrofisico di Catania (IT), University of Palermo (IT)
European Commission, Università degli Studi di Palermo
Openalex Percentile: Top 12%
Advanced Radiotherapy Techniques
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dosimetric evaluation using EPR/alanine and radiochromic film detectors in end-to-end brain stereotactic radiosurgery sessions — Alvaro de Farias Soares, Salvatore Gallo, et al. · Journal of Radioanalytical and Nuclear Chemistry (2025) | TGRS Research Map | TGRS