Localized Thermal Analysis for Sportswear via Wind Tunnel Testing

Thermal comfort of sportswear is critical for optimizing athletic performance and improving safety. However, current research on the convective heat transfer coefficient (h) between fabrics and the air flow remains limited, especially in terms of its local analysis. In this study, a thermal cylinder which simulates human limb was developed to evaluate the fabrics' thermal insulation (It) and h (both local and global values) in the wind tunnel. The wind speed ranged from 2 to 8 m/s, and the stretch ratio (SR) from 1.1 to 2.0. The results show that for both fabrics, the local h reaches a minimum around θ = 80°-90°, while the local It peaks near θ = 120°. The effects of SR and wind speed on It and h are also reported. This work offers a practical method for quantifying the heat transfer characteristics of stretched fabrics, providing theoretical guidance for sportswear design and thermal regulation strategies in wind environment.

Authors

Institutions

Publication Details

Published
2025-01-01
DOI
https://doi.org/10.5220/0013689400003988
Primary Topic
Textile materials and evaluations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Localized Thermal Analysis for Sportswear via Wind Tunnel Testing

Peng Zhou, Zi-Xiang Hu, Xiaoyi Cai
Textile materials and evaluations
article

Localized Thermal Analysis for Sportswear via Wind Tunnel Testing

Peng Zhou, Zi-Xiang Hu, Xiaoyi Cai
article en

Abstract

Thermal comfort of sportswear is critical for optimizing athletic performance and improving safety. However, current research on the convective heat transfer coefficient (h) between fabrics and the air flow remains limited, especially in terms of its local analysis. In this study, a thermal cylinder which simulates human limb was developed to evaluate the fabrics' thermal insulation (It) and h (both local and global values) in the wind tunnel. The wind speed ranged from 2 to 8 m/s, and the stretch ratio (SR) from 1.1 to 2.0. The results show that for both fabrics, the local h reaches a minimum around θ = 80°-90°, while the local It peaks near θ = 120°. The effects of SR and wind speed on It and h are also reported. This work offers a practical method for quantifying the heat transfer characteristics of stretched fabrics, providing theoretical guidance for sportswear design and thermal regulation strategies in wind environment.

Hong Kong University of Science and Technology (HK)
Openalex Percentile: Top 73%
Textile materials and evaluations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.