Evaluation of Non-Proprietary Ultra-High-Performance Concrete (UHPC) to Resistance of Freeze–Thaw

UHPC has been found to have excellent freeze–thaw durability in cold regions. Previous UHPC testing performed has mostly focused on concrete with compressive strength above 21 ksi (145 MPa). In this study, testing was conducted to determine at what strength level concrete transitions to provide excellent freeze–thaw (F–T) performance. Non-proprietary concrete samples were made for freeze–thaw durability from four different concrete mixture designs: 12–15 ksi, 15–18 ksi, 18–21 ksi, and 21+ ksi (83–145+ MPa), and these were tested according to ASTM C666, using 1.5% steel fibers. The samples were made for three different curing regimens: limewater curing in a fog room, simulated precast curing, and steam curing. Low-temperature differential scanning calorimetry (DSC) and mercury intrusion porosimetry (MIP) tests were carried out to reveal the freeze–thaw mechanism of the concrete samples. All mixtures with compressive strength above 15 ksi (103 MPa) performed excellent in freeze–thaw testing with no damage seen. Steam curing was found to negatively affect the freeze–thaw performance at the lowest strength level tested.

Authors

Institutions

Publication Details

Journal
CivilEng
Published
2025-10-23
DOI
https://doi.org/10.3390/civileng6040057
Primary Topic
Concrete and Cement Materials Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Non-Proprietary Ultra-High-Performance Concrete (UHPC) to Resistance of Freeze–Thaw

Megan S. Voss, Emad Alshammari, Kyle A. Riding, Raid S. Alrashidi et al.
CivilEng
Concrete and Cement Materials Research
article

Evaluation of Non-Proprietary Ultra-High-Performance Concrete (UHPC) to Resistance of Freeze–Thaw

Megan S. Voss, Emad Alshammari, Kyle A. Riding, Raid S. Alrashidi, Ali Alsubeai
article en

Abstract

UHPC has been found to have excellent freeze–thaw durability in cold regions. Previous UHPC testing performed has mostly focused on concrete with compressive strength above 21 ksi (145 MPa). In this study, testing was conducted to determine at what strength level concrete transitions to provide excellent freeze–thaw (F–T) performance. Non-proprietary concrete samples were made for freeze–thaw durability from four different concrete mixture designs: 12–15 ksi, 15–18 ksi, 18–21 ksi, and 21+ ksi (83–145+ MPa), and these were tested according to ASTM C666, using 1.5% steel fibers. The samples were made for three different curing regimens: limewater curing in a fog room, simulated precast curing, and steam curing. Low-temperature differential scanning calorimetry (DSC) and mercury intrusion porosimetry (MIP) tests were carried out to reveal the freeze–thaw mechanism of the concrete samples. All mixtures with compressive strength above 15 ksi (103 MPa) performed excellent in freeze–thaw testing with no damage seen. Steam curing was found to negatively affect the freeze–thaw performance at the lowest strength level tested.

CivilEngVol. 6(4)
University of Evansville (US), Royal Commission for Jubail and Yanbu (SA), University of Florida (US), University of Ha'il (SA)
U.S. Department of Transportation, Florida Department of Transportation
Openalex Percentile: Top 68%
Concrete and Cement Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of Non-Proprietary Ultra-High-Performance Concrete (UHPC) to Resistance of Freeze–Thaw — Megan S. Voss, Emad Alshammari, et al. · CivilEng (2025) | TGRS Research Map | TGRS