Why and When ICD Leads Are Extracted: Does the ICD Lead Model Influence Lead Survival?

<i>Background and Objectives</i>: There is limited knowledge on ICD lead lifespan, the reasons for lead failure, and the influence of lead models. Our aim in this study was to compare the lifetime of individual lead models and the reasons for their extraction. <i>Materials and Methods</i>: We analyzed 3929 transvenous lead extractions (TLEs) (including 1068 ICD lead extractions). <i>Results</i>: The median age of an ICD lead removed (for all causes) was 61 months, three years shorter than that of PM leads. Old models with thick leads survived almost twice as long as thin and modern leads. ICD leads were removed due to infection (35.6%), mechanical damage (33.6%), and dysfunction (including perforation) (20.8%). Riata leads presented higher resistance to mechanical damage compared to Sprint Fidelis and Linox (dwell time medians; 124.0, 47.0 and 70.0 months). However, Durata leads presented higher resistance to mechanical damage compared to Sprint Fidelis and Linox (dwell time medians; 81.0, 68.0 and 70.0 months). Riata leads lasted almost twice as long as Sprint Fidelis. Linox leads lasted as long as theoretically fail-safe Sprint Quatro leads. <i>Conclusions</i>: 1. The median of ICD lead survival was three years shorter than that of PM leads. 2. ICD leads were most commonly removed due to infection, mechanical lead damage, and undamaged lead dysfunction (including perforation). 3. Old models of thick leads (Sprint, Ventritex, and Kainox) survived almost twice as long as thin leads from the transition period (Riata and Sprint Fidelis) and modern leads. Despite advances in the design of ICD leads, their lifetime has not changed significantly.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2025-10-23
DOI
https://doi.org/10.3390/medicina61111899
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Why and When ICD Leads Are Extracted: Does the ICD Lead Model Influence Lead Survival?

Dorota Nowosielecka, Tomasz Kukulski, Wojciech Jacheć, Andrzej Kutarski et al.
Medicina
Cardiac pacing and defibrillation studies
article

Why and When ICD Leads Are Extracted: Does the ICD Lead Model Influence Lead Survival?

Dorota Nowosielecka, Tomasz Kukulski, Wojciech Jacheć, Andrzej Kutarski, Łukasz Tułecki, Paweł Stefańczyk
article en

Abstract

<i>Background and Objectives</i>: There is limited knowledge on ICD lead lifespan, the reasons for lead failure, and the influence of lead models. Our aim in this study was to compare the lifetime of individual lead models and the reasons for their extraction. <i>Materials and Methods</i>: We analyzed 3929 transvenous lead extractions (TLEs) (including 1068 ICD lead extractions). <i>Results</i>: The median age of an ICD lead removed (for all causes) was 61 months, three years shorter than that of PM leads. Old models with thick leads survived almost twice as long as thin and modern leads. ICD leads were removed due to infection (35.6%), mechanical damage (33.6%), and dysfunction (including perforation) (20.8%). Riata leads presented higher resistance to mechanical damage compared to Sprint Fidelis and Linox (dwell time medians; 124.0, 47.0 and 70.0 months). However, Durata leads presented higher resistance to mechanical damage compared to Sprint Fidelis and Linox (dwell time medians; 81.0, 68.0 and 70.0 months). Riata leads lasted almost twice as long as Sprint Fidelis. Linox leads lasted as long as theoretically fail-safe Sprint Quatro leads. <i>Conclusions</i>: 1. The median of ICD lead survival was three years shorter than that of PM leads. 2. ICD leads were most commonly removed due to infection, mechanical lead damage, and undamaged lead dysfunction (including perforation). 3. Old models of thick leads (Sprint, Ventritex, and Kainox) survived almost twice as long as thin leads from the transition period (Riata and Sprint Fidelis) and modern leads. Despite advances in the design of ICD leads, their lifetime has not changed significantly.

MedicinaVol. 61(11)
Medical University of Silesia (PL), University of Management and Administration in Zamosc (PL), John Paul II Hospital (PL), State Higher School of Vocational Education in Zamość (PL)
Openalex Percentile: Top 54%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.