Study on the Influence of Winding Height on the Short-Circuit Withstand Capability of 110 kV Transformers
The short-circuit withstanding capability of a transformer is a critical indicator for evaluating its operational reliability. This study investigates the influence of the low-voltage winding height, a key structural parameter, on the electromagnetic forces induced by short-circuit currents and the resultant short-circuit withstand capability. First, theoretical calculation formulas for the transformer leakage magnetic field and winding electromagnetic forces were derived, establishing a foundation for subsequent analysis. Subsequently, two 110 kV transformers, identical in all structural parameters except for their low-voltage winding heights, were selected as case studies. Three-dimensional finite element models were constructed to perform detailed simulations and a comparative analysis of the leakage magnetic field distribution and electromagnetic forces under short-circuit conditions. Finally, practical short-circuit tests were conducted on both transformers for experimental validation, monitoring and comparison of their short-circuit reactance variation curves. Furthermore, a CNN-LSTM model, utilizing the winding axial height of a 110 kV three-phase three-limb transformer as the characteristic parameter, is developed to detect short-circuit fault damage in such transformers with varying winding heights. Through a combined approach of theoretical analysis, simulation, and experimental verification, this study confirms that the low-voltage winding height was a crucial factor affecting the transformer's short-circuit withstand capability of the transformer. Studies have shown that with the increase in the height of low-voltage windings, the leakage magnetic flux of the low-voltage windings increases by 36%, the radial electromagnetic force increases by 37.5%, and the axial electromagnetic force increases by 8.5%. Excessively tall windings amplify radial electromagnetic forces, compromising mechanical stability and consequently increasing the risk of damage during short-circuit faults.
Authors
- Ziyuan Xin (ORCID: https://orcid.org/0000-0002-5370-3143)
- Sijun Wang (ORCID: https://orcid.org/0009-0007-3686-458X)
- Chih-Che Tai
- Tian Tian (ORCID: https://orcid.org/0000-0002-3406-7305)
- Xiaokang Wang (ORCID: https://orcid.org/0000-0001-7167-5062)
- Yukun Ma (ORCID: https://orcid.org/0000-0002-4419-4287)
- Dezhi Chen (ORCID: https://orcid.org/0000-0001-9906-8627)
- Xiu Zhou
Institutions
- Shenyang University of Technology (CN)
- Shanghai Electric (China) (CN)
Publication Details
- Journal
- Sensors
- Published
- 2025-10-23
- DOI
- https://doi.org/10.3390/s25216528
- Primary Topic
- Power Transformer Diagnostics and Insulation
- Type
- article
- Field-Weighted Citation Impact
- 0.00