The Validity and Reliability of the Force Plates and the Linear Position Transducer in Measuring Countermovement Depth and Velocity During Countermovement Jump

Countermovement jump (CMJ) is a key test for evaluating lower-limb neuromuscular function, and accurate measurement of countermovement depth (CMD) and countermovement velocity (CMV) is critical for determining optimal performance. However, the measurement validity and reliability of CMD and CMV-particularly when obtained from force plates (FP) and linear position transducers (LPT)-have remained uncertain. This study determined the validity and reliability of FP and LPT for measuring CMD and CMV. Twenty-eight male recreational athletes performed the CMJ test, and the variables were synchronously acquired by Motion Capture (MC), FP, and LPT. The test was divided into two sessions, with participants completing three maximal effort CMJs per session, and the second session occurred more than 48 h after the first. The reliability was evaluated using the intraclass correlation coefficient (ICC), and the validity was evaluated with linear Pearson's correlation coefficient (r), one-way ANOVA with repeated measures, and Bland-Altman plots. The reliability results for FP and LPT indicated good to excellent (ICC = 0.809-0.900). Compared with MC, the FP showed a high to very high correlation (r = 0.894-0.937), and the LPT showed a high correlation (r = 0.721-0.726). When precise quantification of CMD/CMV is required, FP should be preferred. If only an LPT is available, it is best used for within-athlete longitudinal monitoring with a consistent setup, and cross-device comparisons should be avoided.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-10-23
DOI
https://doi.org/10.3390/s25216542
Citations
1
Primary Topic
Winter Sports Injuries and Performance
Type
article
Field-Weighted Citation Impact
1.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Validity and Reliability of the Force Plates and the Linear Position Transducer in Measuring Countermovement Depth and Velocity During Countermovement Jump

Wenfei Zhu, Qian Xie, Yuliang Sun, Zheng’ao Li et al.
1 citations
Sensors
Winter Sports Injuries and Performance
1.52
article

The Validity and Reliability of the Force Plates and the Linear Position Transducer in Measuring Countermovement Depth and Velocity During Countermovement Jump

Wenfei Zhu, Qian Xie, Yuliang Sun, Zheng’ao Li, Ling Zhang, Wenyue Ma
article en
1 citations

Abstract

Countermovement jump (CMJ) is a key test for evaluating lower-limb neuromuscular function, and accurate measurement of countermovement depth (CMD) and countermovement velocity (CMV) is critical for determining optimal performance. However, the measurement validity and reliability of CMD and CMV-particularly when obtained from force plates (FP) and linear position transducers (LPT)-have remained uncertain. This study determined the validity and reliability of FP and LPT for measuring CMD and CMV. Twenty-eight male recreational athletes performed the CMJ test, and the variables were synchronously acquired by Motion Capture (MC), FP, and LPT. The test was divided into two sessions, with participants completing three maximal effort CMJs per session, and the second session occurred more than 48 h after the first. The reliability was evaluated using the intraclass correlation coefficient (ICC), and the validity was evaluated with linear Pearson's correlation coefficient (r), one-way ANOVA with repeated measures, and Bland-Altman plots. The reliability results for FP and LPT indicated good to excellent (ICC = 0.809-0.900). Compared with MC, the FP showed a high to very high correlation (r = 0.894-0.937), and the LPT showed a high correlation (r = 0.721-0.726). When precise quantification of CMD/CMV is required, FP should be preferred. If only an LPT is available, it is best used for within-athlete longitudinal monitoring with a consistent setup, and cross-device comparisons should be avoided.

SensorsVol. 25(21)
Shaanxi Normal University (CN)
Openalex Percentile: Top 13%
Winter Sports Injuries and Performance
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Validity and Reliability of the Force Plates and the Linear Position Transducer in Measuring Countermovement Depth and Velocity During Countermovement Jump — Wenfei Zhu, Qian Xie, et al. · Sensors (2025) | TGRS Research Map | TGRS