Occipital Bone Erosion Caused by C1 Lateral Mass Screw-Rod Construct Used for C1/2 Arthrodesis: A Case Report

C1 lateral mass screw (C1LMS) is used as a standard implant for fixation of the upper cervical spine. The most significant benefit of the fixation using C1LMS is that it can obtain an excellent mechanical stability immediately after surgery without a massive structural bone graft and strict orthosis. Meanwhile, several studies have already referred to complications, which have not been seen in conventional devices. As for one of the complications, occipital bone erosion (OcBE) induced by repetitive impingement between the occipital bone and the protruded metal implant on the C1 posterior has been rarely reported. OcBE develops infrequently and leads to serious complications, including cerebrospinal fluid leakage and intracranial hemorrhaging. A 78-year-old male case with OcBE, which developed after atlantoaxial arthrodesis using C1 lateral mass and C2 translaminar screws, was presented. In the current case, increased O-C2 angle compensating the subaxial kyphosis, protrusion of C1LMS-rod construct, and cephalad located entry point of C1LMS are related to the occurrence of OcBE.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-10-23
DOI
https://doi.org/10.7759/cureus.95257
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Occipital Bone Erosion Caused by C1 Lateral Mass Screw-Rod Construct Used for C1/2 Arthrodesis: A Case Report

Chikage Sato, Koichiro Okuyama, Tadato Kido, Genki Tojo
Cureus
Spinal Fractures and Fixation Techniques
article

Occipital Bone Erosion Caused by C1 Lateral Mass Screw-Rod Construct Used for C1/2 Arthrodesis: A Case Report

Chikage Sato, Koichiro Okuyama, Tadato Kido, Genki Tojo
article en

Abstract

C1 lateral mass screw (C1LMS) is used as a standard implant for fixation of the upper cervical spine. The most significant benefit of the fixation using C1LMS is that it can obtain an excellent mechanical stability immediately after surgery without a massive structural bone graft and strict orthosis. Meanwhile, several studies have already referred to complications, which have not been seen in conventional devices. As for one of the complications, occipital bone erosion (OcBE) induced by repetitive impingement between the occipital bone and the protruded metal implant on the C1 posterior has been rarely reported. OcBE develops infrequently and leads to serious complications, including cerebrospinal fluid leakage and intracranial hemorrhaging. A 78-year-old male case with OcBE, which developed after atlantoaxial arthrodesis using C1 lateral mass and C2 translaminar screws, was presented. In the current case, increased O-C2 angle compensating the subaxial kyphosis, protrusion of C1LMS-rod construct, and cephalad located entry point of C1LMS are related to the occurrence of OcBE.

CureusVol. 17(10)
Akita University Hospital (JP)
Openalex Percentile: Top 52%
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Occipital Bone Erosion Caused by C1 Lateral Mass Screw-Rod Construct Used for C1/2 Arthrodesis: A Case Report — Chikage Sato, Koichiro Okuyama, et al. · Cureus (2025) | TGRS Research Map | TGRS