Impact of patient-specific deep learning lung organs-at-risk segmentation on accumulated dose in online adaptive 0.35 T MR-guided radiotherapy

<i>Objective.</i>Online adaptation in magnetic resonance imaging-guided radiotherapy (MRgRT) for lung cancer is hindered by time-consuming organs-at-risk (OARs) recontouring on daily MR images (dMRIs) and inter-/intra-observer variability. Deep learning auto-segmentation of OARs offers an efficient alternative. While baseline models (BMs) provide general segmentation, patient-specific (PS) training using expert-delineated planning MR images (pMRIs) can enhance accuracy. This study evaluated accumulated dose differences between BM and PS OAR models without manual modification in online plan adaptation.<i>Approach.</i>Eleven lung cancer patients treated with a 0.35 T magnetic resonance linear accelerator were retrospectively analyzed. Pre-trained population-based 3D U-Nets (BM) for nine thoracic OARs served as initial models for PS fine-tuning on planning MRIs. BM- and PS-generated OAR contours per fraction were imported into an MRgRT treatment planning system, along with clinical expert target contours. Online adaptive doses were re-optimized using both models' OAR contours with the same clinical objective functions. Fraction doses were accumulated on the pMRI, and dose-volume histogram parameters of PTV, GTV, and other OARs within PTV + 3 cm were calculated using clinical contours on pMRI. A Wilcoxon signed-rank test was used to test for statistical differences (<i>α</i> = 0.05) compared to accumulated clinical doses.<i>Main results.</i>PS models improved segmentation accuracy for all OARs compared to BM. They also mitigated substantial outliers inD1ccBMversusD1ccclinicaland resulted in higher PTVD95%and GTVD98%than clinical plans. Overall,DBMmet 48/61 OAR constraints, whileDPSmet 53. For PTVs, bothDPSandDBMsatisfied 21/25 constraints.<i>Significance.</i>Unmodified BM and PS model contours yielded median accumulated doses comparable to clinically delivered doses. However, PS models demonstrated superior geometric alignment, improved OAR sparing, and enhanced target coverage compared to BM, potentially benefiting MRgRT lung cancer patients.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-10-23
DOI
https://doi.org/10.1088/1361-6560/ae16fb
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of patient-specific deep learning lung organs-at-risk segmentation on accumulated dose in online adaptive 0.35 T MR-guided radiotherapy

Stefanie Corradini, Sebastian Marschner, Claus Belka, Maria Kawula et al.
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
article

Impact of patient-specific deep learning lung organs-at-risk segmentation on accumulated dose in online adaptive 0.35 T MR-guided radiotherapy

Stefanie Corradini, Sebastian Marschner, Claus Belka, Maria Kawula, Christopher Kurz, Moritz Rabe, Guillaume Landry, Yuqing Xiong
article en

Abstract

<i>Objective.</i>Online adaptation in magnetic resonance imaging-guided radiotherapy (MRgRT) for lung cancer is hindered by time-consuming organs-at-risk (OARs) recontouring on daily MR images (dMRIs) and inter-/intra-observer variability. Deep learning auto-segmentation of OARs offers an efficient alternative. While baseline models (BMs) provide general segmentation, patient-specific (PS) training using expert-delineated planning MR images (pMRIs) can enhance accuracy. This study evaluated accumulated dose differences between BM and PS OAR models without manual modification in online plan adaptation.<i>Approach.</i>Eleven lung cancer patients treated with a 0.35 T magnetic resonance linear accelerator were retrospectively analyzed. Pre-trained population-based 3D U-Nets (BM) for nine thoracic OARs served as initial models for PS fine-tuning on planning MRIs. BM- and PS-generated OAR contours per fraction were imported into an MRgRT treatment planning system, along with clinical expert target contours. Online adaptive doses were re-optimized using both models' OAR contours with the same clinical objective functions. Fraction doses were accumulated on the pMRI, and dose-volume histogram parameters of PTV, GTV, and other OARs within PTV + 3 cm were calculated using clinical contours on pMRI. A Wilcoxon signed-rank test was used to test for statistical differences (<i>α</i> = 0.05) compared to accumulated clinical doses.<i>Main results.</i>PS models improved segmentation accuracy for all OARs compared to BM. They also mitigated substantial outliers inD1ccBMversusD1ccclinicaland resulted in higher PTVD95%and GTVD98%than clinical plans. Overall,DBMmet 48/61 OAR constraints, whileDPSmet 53. For PTVs, bothDPSandDBMsatisfied 21/25 constraints.<i>Significance.</i>Unmodified BM and PS model contours yielded median accumulated doses comparable to clinically delivered doses. However, PS models demonstrated superior geometric alignment, improved OAR sparing, and enhanced target coverage compared to BM, potentially benefiting MRgRT lung cancer patients.

Physics in Medicine and BiologyVol. 70(22)
LMU Klinikum (DE), German Centre for Cardiovascular Research (DE), Ludwig-Maximilians-Universität München (DE)
Openalex Percentile: Top 60%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.