Continuous measurement of pulse arrival time for identification of blood pressure changes in patients undergoing hemodialysis—a feasibility study

The study demonstrates that tracking BP changes using PAT as a non-invasive method in hemodialysis patients is feasible. However, the reliability of PAT measurements appears to vary among patients, indicating that this method may not be universally applicable. The observed inverse association between PAT and BP changes, especially during the start to middle phase of dialysis, highlights the potential of this technique to complement traditional monitoring methods. These exploratory findings open avenues for further research to validate the utility of PAT, particularly in predicting IDH episodes and assessing its behavior in scenarios of low BP or minimal variations.

Authors

Institutions

Publication Details

Journal
Clinical Kidney Journal
Published
2025-10-22
DOI
https://doi.org/10.1093/ckj/sfaf255
Citations
1
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Continuous measurement of pulse arrival time for identification of blood pressure changes in patients undergoing hemodialysis—a feasibility study

Uwe Heemann, Stefan Orter, Martin Bachler, Christoph Schmaderer et al.
1 citations
Clinical Kidney Journal
Hemodynamic Monitoring and Therapy
2.01
article

Continuous measurement of pulse arrival time for identification of blood pressure changes in patients undergoing hemodialysis—a feasibility study

Uwe Heemann, Stefan Orter, Martin Bachler, Christoph Schmaderer, Siegfried Wassertheurer, Simon Krenn, Claudius Küchle, Marius Wunderle, Christopher Mayer, Bernhard Hametner, David Stadler
article en
1 citations

Abstract

The study demonstrates that tracking BP changes using PAT as a non-invasive method in hemodialysis patients is feasible. However, the reliability of PAT measurements appears to vary among patients, indicating that this method may not be universally applicable. The observed inverse association between PAT and BP changes, especially during the start to middle phase of dialysis, highlights the potential of this technique to complement traditional monitoring methods. These exploratory findings open avenues for further research to validate the utility of PAT, particularly in predicting IDH episodes and assessing its behavior in scenarios of low BP or minimal variations.

Clinical Kidney JournalVol. 18(11)
AIT Austrian Institute of Technology GmbH (AT), TUM Klinikum (DE), Technical University of Munich (DE), Medical University of Vienna (AT)
Openalex Percentile: Top 11%
Hemodynamic Monitoring and Therapy
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.