Assessment of Subclinical Fluid Overload in Patients with Hypertension on Maintenance Hemodiafiltration

Background: Fluid overload is one of the main mechanisms associated with the presence of hypertension in dialysis patients. Traditional assessment of volume status relies on physical exam (PE) and ultrasonographic evaluation. The aim was to evaluate the prevalence of subclinical fluid overload with Bioelectrical Impedance Analysis (BIA) in patients with hypertension on maintenance hemodiafiltration (HDF) and to determine associated factors. Methods: This cross-sectional study included patients on maintenance HDF with hypertension defined as pre-dialysis blood pressure (BP) ≥140/90 mmHg or post-dialysis BP ≥130/80 mmHg despite being at its clinical dry weight. Volume status was assessed by PE, lung ultrasound, Venous Excess Ultrasound Score (VExUS) and BIA InBody s10. Subclinical volume overload was defined as the presence of edema on BIA despite normal physical examination and ultrasound evaluation. The data were expressed in medians and interquartile ranges (IQR). Results: Of 45 patients on maintenance HDF, 10 meet the inclusion criteria. Median age was 38.5 years [32-58.5], 60% were women. Pre-dialysis BP was 165/84 mmHg [142/77-182/90] and post-dialysis BP was 157/88 mmHg [145/74-167/91]. 40% of the population had subclinical fluid overload due to BIA. Associated factors with subclinical fluid overload were the age and the post-dialysis minimum diameter of the IVC (Table 1). A higher post-dialysis pulse pressure (PP) (95 [93-97.5] vs 74.5 [60-87], p = 0.036) and a lower post-dialysis heart rate (HR) (66 [65-66.5] vs 81 [74-87], p = 0.037) were associated with subclinical volume overload when this was determined by intracellular water. Conclusion: BIA is a tool for assessing volume status which can detect subclinical fluid overload in patients with hypertension on maintenance HDF. Age and post-dialysis minimum diameter of the IVC were associated factors.Comparison of clinical factors in patients with and without subclinical fluid overload

Authors

Institutions

Publication Details

Journal
Journal of the American Society of Nephrology
Published
2025-10-01
DOI
https://doi.org/10.1681/asn.2025xbgd9tpb
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Subclinical Fluid Overload in Patients with Hypertension on Maintenance Hemodiafiltration

Salvador Lopez Gil, Eduardo Zúñiga, Luis Daniel Ramírez-Calvillo, Juan Pablo Durán et al.
Journal of the American Society of Nephrology
Dialysis and Renal Disease Management
article

Assessment of Subclinical Fluid Overload in Patients with Hypertension on Maintenance Hemodiafiltration

Salvador Lopez Gil, Eduardo Zúñiga, Luis Daniel Ramírez-Calvillo, Juan Pablo Durán, Gabriela Leal Escobar, Luis Andres Segovia, Maria Luisa Romero
article en

Abstract

Background: Fluid overload is one of the main mechanisms associated with the presence of hypertension in dialysis patients. Traditional assessment of volume status relies on physical exam (PE) and ultrasonographic evaluation. The aim was to evaluate the prevalence of subclinical fluid overload with Bioelectrical Impedance Analysis (BIA) in patients with hypertension on maintenance hemodiafiltration (HDF) and to determine associated factors. Methods: This cross-sectional study included patients on maintenance HDF with hypertension defined as pre-dialysis blood pressure (BP) ≥140/90 mmHg or post-dialysis BP ≥130/80 mmHg despite being at its clinical dry weight. Volume status was assessed by PE, lung ultrasound, Venous Excess Ultrasound Score (VExUS) and BIA InBody s10. Subclinical volume overload was defined as the presence of edema on BIA despite normal physical examination and ultrasound evaluation. The data were expressed in medians and interquartile ranges (IQR). Results: Of 45 patients on maintenance HDF, 10 meet the inclusion criteria. Median age was 38.5 years [32-58.5], 60% were women. Pre-dialysis BP was 165/84 mmHg [142/77-182/90] and post-dialysis BP was 157/88 mmHg [145/74-167/91]. 40% of the population had subclinical fluid overload due to BIA. Associated factors with subclinical fluid overload were the age and the post-dialysis minimum diameter of the IVC (Table 1). A higher post-dialysis pulse pressure (PP) (95 [93-97.5] vs 74.5 [60-87], p = 0.036) and a lower post-dialysis heart rate (HR) (66 [65-66.5] vs 81 [74-87], p = 0.037) were associated with subclinical volume overload when this was determined by intracellular water. Conclusion: BIA is a tool for assessing volume status which can detect subclinical fluid overload in patients with hypertension on maintenance HDF. Age and post-dialysis minimum diameter of the IVC were associated factors.Comparison of clinical factors in patients with and without subclinical fluid overload

Journal of the American Society of NephrologyVol. 36(10S)
Instituto Nacional de Cardiologia (BR), Instituto Nacional de Cardiología (MX)
Openalex Percentile: Top 65%
Dialysis and Renal Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.