Exploring a Predictive System for Intradialytic Hypotension Using Optical Blood Flow Monitoring

Background: Peripheral artery disease (PAD), especially lower extremity artery disease (LEAD) and chronic limb-threatening ischemia (CLTI), is highly prevalent in hemodialysis patients and is associated with poor prognosis including lower limb amputation and cardiovascular mortality. In particular, intradialytic hypotension (IDH) has been identified as an independent risk factor for PAD onset and progression. To investigate the dynamic changes in peripheral vascular resistance during hemodialysis using diffuse correlation spectroscopy (DCS), and to evaluate whether these changes are associated with dialysis blood pressure decline. Methods: We conducted a prospective observational study involving maintenance hemodialysis patients. Muscle blood flow in the anterior tibialis was continuously monitored using a bedside DCS system during a standard hemodialysis session. Blood pressure was measured every 30 to 60 minutes. Tissue perfusion depth was adjusted to ~1.5 cm by varying the distance between the light source and detector probes. Peripheral vascular resistance was calculated by dividing mean arterial pressure by muscle blood flow. Results: At the time of analysis with 13 patients, those with a significant decline in blood pressure by the end of dialysis (drop group, n = 5) showed a notable reduction in peripheral vascular resistance. A strong positive correlation (r = 0.83, p < 0.01) was observed between end-of-dialysis blood pressure and peripheral vascular resistance normalized to baseline. This relationship was preserved even when vascular resistance measured at 50% and 75% of dialysis duration was analyzed. These results suggest that impaired sympathetic vasoconstriction or autonomic dysregulation may lead to failure in maintaining vascular resistance, resulting in reduced venous return and blood pressure. Conclusion: Real-time monitoring of muscle blood flow using DCS revealed a close association between decreased peripheral vascular resistance and intradialytic blood pressure decline. Our findings highlight the utility of DCS in identifying hemodialysis patients at risk for hypotension by detecting early vascular response impairment.

Authors

Institutions

Publication Details

Journal
Journal of the American Society of Nephrology
Published
2025-10-01
DOI
https://doi.org/10.1681/asn.2025xhz357eg
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring a Predictive System for Intradialytic Hypotension Using Optical Blood Flow Monitoring

Tsutomu Sakurada, Shigeki Kojima, Suguru Takayama, Yugo Shibagaki
Journal of the American Society of Nephrology
Hemodynamic Monitoring and Therapy
article

Exploring a Predictive System for Intradialytic Hypotension Using Optical Blood Flow Monitoring

Tsutomu Sakurada, Shigeki Kojima, Suguru Takayama, Yugo Shibagaki
article en

Abstract

Background: Peripheral artery disease (PAD), especially lower extremity artery disease (LEAD) and chronic limb-threatening ischemia (CLTI), is highly prevalent in hemodialysis patients and is associated with poor prognosis including lower limb amputation and cardiovascular mortality. In particular, intradialytic hypotension (IDH) has been identified as an independent risk factor for PAD onset and progression. To investigate the dynamic changes in peripheral vascular resistance during hemodialysis using diffuse correlation spectroscopy (DCS), and to evaluate whether these changes are associated with dialysis blood pressure decline. Methods: We conducted a prospective observational study involving maintenance hemodialysis patients. Muscle blood flow in the anterior tibialis was continuously monitored using a bedside DCS system during a standard hemodialysis session. Blood pressure was measured every 30 to 60 minutes. Tissue perfusion depth was adjusted to ~1.5 cm by varying the distance between the light source and detector probes. Peripheral vascular resistance was calculated by dividing mean arterial pressure by muscle blood flow. Results: At the time of analysis with 13 patients, those with a significant decline in blood pressure by the end of dialysis (drop group, n = 5) showed a notable reduction in peripheral vascular resistance. A strong positive correlation (r = 0.83, p < 0.01) was observed between end-of-dialysis blood pressure and peripheral vascular resistance normalized to baseline. This relationship was preserved even when vascular resistance measured at 50% and 75% of dialysis duration was analyzed. These results suggest that impaired sympathetic vasoconstriction or autonomic dysregulation may lead to failure in maintaining vascular resistance, resulting in reduced venous return and blood pressure. Conclusion: Real-time monitoring of muscle blood flow using DCS revealed a close association between decreased peripheral vascular resistance and intradialytic blood pressure decline. Our findings highlight the utility of DCS in identifying hemodialysis patients at risk for hypotension by detecting early vascular response impairment.

Journal of the American Society of NephrologyVol. 36(10S)
St. Marianna University School of Medicine (JP)
Openalex Percentile: Top 52%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.