Fundamental Sensor Response Time Limitations of Practical Air Temperature Measurement

Abstract Air temperature measurements in naturally ventilated thermometer screens underpin the instrumental climate record. Increasing automation is, however, revealing limitations. One is through thermometer time response, especially in light winds or calm conditions, often at the daily temperature minimum. The exponential time response for thermometers enclosed within a Stevenson screen is a key parameter, but poorly known. Here, is evaluated in a practical experimental situation against the World Meteorological Organization (WMO)'s recommended sensor s. We find increases with sensor diameter , with only a = 2 mm sensor meeting WMO expectations, even then requiring ambient wind speeds . Typical = 4 mm sensors never meet the criterion when either force‐ or naturally ventilated, with mins in a naturally ventilated arrangement under calm conditions. Inadequate will lead to underestimation of the diurnal temperature range or other local measures derived from daily temperature maxima and minima.

Authors

Institutions

Publication Details

Journal
Geophysical Research Letters
Published
2025-10-23
DOI
https://doi.org/10.1029/2025gl118464
Citations
1
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fundamental Sensor Response Time Limitations of Practical Air Temperature Measurement

Stephen Burt, R. G. Harrison
1 citations
Geophysical Research Letters
Advanced Sensor Technologies Research
0.67
article

Fundamental Sensor Response Time Limitations of Practical Air Temperature Measurement

Stephen Burt, R. G. Harrison
article en
1 citations

Abstract

Abstract Air temperature measurements in naturally ventilated thermometer screens underpin the instrumental climate record. Increasing automation is, however, revealing limitations. One is through thermometer time response, especially in light winds or calm conditions, often at the daily temperature minimum. The exponential time response for thermometers enclosed within a Stevenson screen is a key parameter, but poorly known. Here, is evaluated in a practical experimental situation against the World Meteorological Organization (WMO)'s recommended sensor s. We find increases with sensor diameter , with only a = 2 mm sensor meeting WMO expectations, even then requiring ambient wind speeds . Typical = 4 mm sensors never meet the criterion when either force‐ or naturally ventilated, with mins in a naturally ventilated arrangement under calm conditions. Inadequate will lead to underestimation of the diurnal temperature range or other local measures derived from daily temperature maxima and minima.

Geophysical Research LettersVol. 52(20)
University of Reading (GB)
University of Reading
Openalex Percentile: Top 25%
Advanced Sensor Technologies Research
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fundamental Sensor Response Time Limitations of Practical Air Temperature Measurement — Stephen Burt, R. G. Harrison · Geophysical Research Letters (2025) | TGRS Research Map | TGRS