SNRAware: Improved Deep Learning MRI Denoising with Signal-to-Noise Ratio Unit Training and G-Factor Map Augmentation

Purpose To develop and evaluate a deep learning-based MRI denoising method using quantitative noise distribution information obtained during image reconstruction to improve model performance and generalization. Materials and Methods This retrospective study included a training set of 2 885 236 images from 96 605 cardiac cine series acquired with 3-T MRI scanners from January 2018 to December 2020. Of these data, 95% were used for training, and 5% were used for validation. The hold-out test set included 3000 cine series, acquired in the same period. Fourteen model architectures were evaluated by instantiating each of the two backbone types with seven transformer and convolution block types. The proposed SNRAware training scheme leveraged MRI reconstruction knowledge to enhance denoising by simulating diverse synthetic datasets and providing quantitative noise distribution information. Internal testing measured performance using peak signal-to-noise ratio and structural similarity index measure, whereas external tests conducted with 1.5-T real-time cardiac cine, first-pass cardiac perfusion, brain, and spine MRI assessed generalization across various sequences, contrast agents, anatomies, and field strengths. Results SNRAware improved performance on internal tests conducted on a hold-out dataset of 3000 cine series. Models trained without reconstruction knowledge achieved the worst performance metrics. Improvement was architecture agnostic for both convolution and transformer models. However, transformer models outperformed their convolutional counterparts. Additionally, three-dimensional input tensors showed improved performance over two-dimensional images. The best-performing model from the internal testing generalized well to external samples, delivering 6.5 and 2.9 times contrast-to-noise ratio improvement for real-time cine and perfusion imaging, respectively. The model trained using only cardiac cine data generalized well to three-dimensional T1-weighted magnetization-prepared rapid gradient-echo brain and T2-weighted turbo spin-echo spine MRI acquisitions. Conclusion The SNRAware training scheme leveraged data obtained during the image reconstruction process for deep learning-based MRI denoising training, resulting in improved performance and good generalization. <b>Keywords:</b> MRI, Deep Learning, MRI Denoising <i>Supplemental material is available for this article.</i> © The Author(s) 2025. Published by the Radiological Society of North America under a CC BY 4.0 license.

Authors

Institutions

Publication Details

Journal
Radiology Artificial Intelligence
Published
2025-10-22
DOI
https://doi.org/10.1148/ryai.250227
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SNRAware: Improved Deep Learning MRI Denoising with Signal-to-Noise Ratio Unit Training and G-Factor Map Augmentation

James Moon, Iain Pierce, Peter Kellman, Sarah Hooper et al.
Radiology Artificial Intelligence
Advanced MRI Techniques and Applications
article

SNRAware: Improved Deep Learning MRI Denoising with Signal-to-Noise Ratio Unit Training and G-Factor Map Augmentation

James Moon, Iain Pierce, Peter Kellman, Sarah Hooper, Thomas A. Treibel, Charlotte Manisty, Joseph Naegele, Hui Xue, Adrienne E. Campbell‐Washburn, Rhodri Davies, Michael S. Hansen, John Stairs
article en

Abstract

Purpose To develop and evaluate a deep learning-based MRI denoising method using quantitative noise distribution information obtained during image reconstruction to improve model performance and generalization. Materials and Methods This retrospective study included a training set of 2 885 236 images from 96 605 cardiac cine series acquired with 3-T MRI scanners from January 2018 to December 2020. Of these data, 95% were used for training, and 5% were used for validation. The hold-out test set included 3000 cine series, acquired in the same period. Fourteen model architectures were evaluated by instantiating each of the two backbone types with seven transformer and convolution block types. The proposed SNRAware training scheme leveraged MRI reconstruction knowledge to enhance denoising by simulating diverse synthetic datasets and providing quantitative noise distribution information. Internal testing measured performance using peak signal-to-noise ratio and structural similarity index measure, whereas external tests conducted with 1.5-T real-time cardiac cine, first-pass cardiac perfusion, brain, and spine MRI assessed generalization across various sequences, contrast agents, anatomies, and field strengths. Results SNRAware improved performance on internal tests conducted on a hold-out dataset of 3000 cine series. Models trained without reconstruction knowledge achieved the worst performance metrics. Improvement was architecture agnostic for both convolution and transformer models. However, transformer models outperformed their convolutional counterparts. Additionally, three-dimensional input tensors showed improved performance over two-dimensional images. The best-performing model from the internal testing generalized well to external samples, delivering 6.5 and 2.9 times contrast-to-noise ratio improvement for real-time cine and perfusion imaging, respectively. The model trained using only cardiac cine data generalized well to three-dimensional T1-weighted magnetization-prepared rapid gradient-echo brain and T2-weighted turbo spin-echo spine MRI acquisitions. Conclusion The SNRAware training scheme leveraged data obtained during the image reconstruction process for deep learning-based MRI denoising training, resulting in improved performance and good generalization. <b>Keywords:</b> MRI, Deep Learning, MRI Denoising <i>Supplemental material is available for this article.</i> © The Author(s) 2025. Published by the Radiological Society of North America under a CC BY 4.0 license.

Radiology Artificial IntelligenceVol. 7(6)
Microsoft (United States) (US), Barts Health NHS Trust (GB), National Heart, Lung, and Blood Institute (US), University College London (GB)
Openalex Percentile: Top 55%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.