White-ray computed tomography using a power light-emitting diode and self-wavelength selection

To image objects, including biomedical samples, we developed a white-ray computed tomography (WRCT) scanner using a white power light-emitting diode (LED) and a high-sensitivity photodiode (PD) module. The line beam forms using a 1.0-mm-diameter 10-mm-length graphite collimator and is irradiated to an object. Photons penetrating an object are detected using the PD module through a 0.7-mm-diameter, 10-mm-length diaphragm. The spatial resolutions were primarily determined by the diaphragm diameter attached to the detector and were ∼0.7 × 0.7 mm2. The WRCT was performed by repeating the reciprocating translations and rotations of the object, and the ray-sampling-translation and rotation steps were 0.1 mm and 0.5°, respectively. The WR consisted of visible and near-infrared photons, and rabbit blood in a vinyl tube was observed at high contrast.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-10-01
DOI
https://doi.org/10.1063/5.0285323
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

White-ray computed tomography using a power light-emitting diode and self-wavelength selection

Osahiko Hagiwara, Jiro Sato, Kazuki Ito, Manabu Watanabe et al.
Review of Scientific Instruments
Digital Radiography and Breast Imaging
article

White-ray computed tomography using a power light-emitting diode and self-wavelength selection

Osahiko Hagiwara, Jiro Sato, Kazuki Ito, Manabu Watanabe, Yuichi Sato, Eiichi Sato, Toshiyuki Enomoto, Ryohei Sato
article en

Abstract

To image objects, including biomedical samples, we developed a white-ray computed tomography (WRCT) scanner using a white power light-emitting diode (LED) and a high-sensitivity photodiode (PD) module. The line beam forms using a 1.0-mm-diameter 10-mm-length graphite collimator and is irradiated to an object. Photons penetrating an object are detected using the PD module through a 0.7-mm-diameter, 10-mm-length diaphragm. The spatial resolutions were primarily determined by the diaphragm diameter attached to the detector and were ∼0.7 × 0.7 mm2. The WRCT was performed by repeating the reciprocating translations and rotations of the object, and the ray-sampling-translation and rotation steps were 0.1 mm and 0.5°, respectively. The WR consisted of visible and near-infrared photons, and rabbit blood in a vinyl tube was observed at high contrast.

Review of Scientific InstrumentsVol. 96(10)
Toho University (JP), Iwate University (JP), Iwate Medical University (JP), Toho University Ohashi Medical Center (JP), Sendai Medical Center (JP)
Openalex Percentile: Top 57%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

White-ray computed tomography using a power light-emitting diode and self-wavelength selection — Osahiko Hagiwara, Jiro Sato, et al. · Review of Scientific Instruments (2025) | TGRS Research Map | TGRS