Characterizing Microstructural and Mechanical Properties of Dancer Achilles Tendon Using Ultrashort Echo Time MRI and Shear Wave Elastography Ultrasound

Previous observations of multi-echo ultrashort echo time (UTE) magnetic resonance imaging (MRI) decay data from the Achilles tendon (AT) report an off-resonance non-water signal associated with non-collagenous extracellular matrix (ECM) constituents. This cross-sectional study investigates the relationship between this MRI-derived tissue matrix signal and mechanical stiffness of the AT in professional ballet dancers and non-dancer adults. Multiexponential analysis of multi-echo UTE MRI was used to quantify water components and an off-resonance AT matrix component. To compare AT structure with its functionality, shear wave elastography (SWE) ultrasound US was used to measure tendon stiffness along both longitudinal (V<sub>L</sub>) and transverse (V<sub>S</sub>) axes. 34 participants, including 15 ballet dancers and 19 non-dancers, were studied. Dancers exhibited significantly larger V<sub>S</sub> (p = 0.013) compared to non-dancers, consistent with prior observations of a training effect in tendon from repeated loading with exercise. UTE-derived off-resonance relaxation component amplitude, β<sub>3</sub>, was positively associated with V<sub>L</sub> in dancers (p = 0.029) and V<sub>S</sub> in non-dancers (p = 0.024), suggesting a microstructural role of this matrix component. While additional work is needed to unambiguously assign this off-resonance signal, these findings suggest its association with non-collagenous ECM and show potential for combined use of UTE and SWE imaging to assess tendon structure-function relationships and adaptations to mechanical loading in vivo.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Research®
Published
2025-10-22
DOI
https://doi.org/10.1002/jor.70075
Primary Topic
Tendon Structure and Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterizing Microstructural and Mechanical Properties of Dancer Achilles Tendon Using Ultrashort Echo Time MRI and Shear Wave Elastography Ultrasound

Courtney N. Gleason, Pan Su, Felix M. Gonzalez, E. Faulkner et al.
Journal of Orthopaedic Research®
Tendon Structure and Treatment
article

Characterizing Microstructural and Mechanical Properties of Dancer Achilles Tendon Using Ultrashort Echo Time MRI and Shear Wave Elastography Ultrasound

Courtney N. Gleason, Pan Su, Felix M. Gonzalez, E. Faulkner, Amanda M. Blackmon, Anna M. Horner, David A. Reiter, Vahid Khalilzad Sharghi, Philip C. Wong, Monica Umpierrez, Damian Dyckman
article en

Abstract

Previous observations of multi-echo ultrashort echo time (UTE) magnetic resonance imaging (MRI) decay data from the Achilles tendon (AT) report an off-resonance non-water signal associated with non-collagenous extracellular matrix (ECM) constituents. This cross-sectional study investigates the relationship between this MRI-derived tissue matrix signal and mechanical stiffness of the AT in professional ballet dancers and non-dancer adults. Multiexponential analysis of multi-echo UTE MRI was used to quantify water components and an off-resonance AT matrix component. To compare AT structure with its functionality, shear wave elastography (SWE) ultrasound US was used to measure tendon stiffness along both longitudinal (V<sub>L</sub>) and transverse (V<sub>S</sub>) axes. 34 participants, including 15 ballet dancers and 19 non-dancers, were studied. Dancers exhibited significantly larger V<sub>S</sub> (p = 0.013) compared to non-dancers, consistent with prior observations of a training effect in tendon from repeated loading with exercise. UTE-derived off-resonance relaxation component amplitude, β<sub>3</sub>, was positively associated with V<sub>L</sub> in dancers (p = 0.029) and V<sub>S</sub> in non-dancers (p = 0.024), suggesting a microstructural role of this matrix component. While additional work is needed to unambiguously assign this off-resonance signal, these findings suggest its association with non-collagenous ECM and show potential for combined use of UTE and SWE imaging to assess tendon structure-function relationships and adaptations to mechanical loading in vivo.

Journal of Orthopaedic Research®Vol. 43(12)
Mercer University (US), Emory University (US), AdventHealth Orlando (US), AdventHealth East Orlando (US), Mercer University Health Sciences Center (US), Independent Dance (GB), Medical Solutions (GB), Endocrine Research Solutions (United States) (US), Siemens (United States) (US), Siemens Healthcare (United States) (US), AdventHealth Foundation Central Florida (US)
Emory University, National Institutes of Health
Openalex Percentile: Top 61%
Tendon Structure and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.