Mechanical assessment of a titanium cervical spine corpectomy cage assembled with 3D-printed patient-specific endplate-conformed contact surfaces and a traditionally manufactured expandable mechanism

This study developed a new titanium cervical spine expandable corpectomy cage (ECC) that consisted of two superior/inferior patient-specific endplate-conformed contact surfaces (PECSs) fabricated through 3D printing and a standardized centrally expandable mechanism (CEM) manufactured using traditional machining. Fatigue testing was conducted to evaluate whether the components of ECC could be assembled using different manufacturing methods to meet the functional testing requirements in compliance with FDA regulations. The titanium 3D-printed superior/inferior PECSs were designed based on the CT images/CAD system to assembly with a CNC milling/precision wire cutting cuboid CEM (14 mm square cross-section) expansion driven by a set of sliders interlocked via key and keyway mechanisms for the ECC of two-segmental vertebral bodies. The ECC underwent FDA-compliant static/dynamic compression, shear, torsion, subsidence tests and finite element (FE) analysis for understanding the stress differences on endplates between PECS and flat-shaped endplate contact surface (FECS). Stiffness/yield strength were found to be 2127 ± 146 N/mm/8547 ± 1213 N for the compression test, 1158 ± 139 N/mm/ 2561 ± 114 N for the shear test, and 1.22 ± 0.32 Nm/deg/16.5 ± 0.58 Nm for the torque test. Some failure samples showed that fixation screws were fractured/loosened under the shear test. The endure limits were 1600 N, 350 N and 1.0 N*m under compression, shear and torsion cyclic load tests, respectively. The results of the static axial compression and static/dynamic compression-shear testing did not meet the acceptance criteria of ISO 23,089. The PECS with higher stiffness value showed that better subsidence resistance was achieved than FECS and was consistent with that the maximum stress value and distribution for the FECS were more harmful than those for the PECS models. This study demonstrated that mechanical testing is essential when assembling 3D-printed components with CNC-manufactured parts in multi-component medical implants, as mismatches in interface behavior may result in mechanical failure. The results of FE analysis and subsidence tests indicated that PECS can decrease stress concentration between the ECC and endplates to present better performance for subsidence resistance.

Authors

Institutions

Publication Details

Journal
3D Printing in Medicine
Published
2025-10-23
DOI
https://doi.org/10.1186/s41205-025-00299-2
Citations
1
Primary Topic
Cervical and Thoracic Myelopathy
Type
article
Field-Weighted Citation Impact
2.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical assessment of a titanium cervical spine corpectomy cage assembled with 3D-printed patient-specific endplate-conformed contact surfaces and a traditionally manufactured expandable mechanism

Wei-Hsiang Sun, Chun‐Li Lin, Shih-Chieh Shen, Shao-Fu Huang
1 citations
3D Printing in Medicine
Cervical and Thoracic Myelopathy
2.01
article

Mechanical assessment of a titanium cervical spine corpectomy cage assembled with 3D-printed patient-specific endplate-conformed contact surfaces and a traditionally manufactured expandable mechanism

Wei-Hsiang Sun, Chun‐Li Lin, Shih-Chieh Shen, Shao-Fu Huang
article en
1 citations

Abstract

This study developed a new titanium cervical spine expandable corpectomy cage (ECC) that consisted of two superior/inferior patient-specific endplate-conformed contact surfaces (PECSs) fabricated through 3D printing and a standardized centrally expandable mechanism (CEM) manufactured using traditional machining. Fatigue testing was conducted to evaluate whether the components of ECC could be assembled using different manufacturing methods to meet the functional testing requirements in compliance with FDA regulations. The titanium 3D-printed superior/inferior PECSs were designed based on the CT images/CAD system to assembly with a CNC milling/precision wire cutting cuboid CEM (14 mm square cross-section) expansion driven by a set of sliders interlocked via key and keyway mechanisms for the ECC of two-segmental vertebral bodies. The ECC underwent FDA-compliant static/dynamic compression, shear, torsion, subsidence tests and finite element (FE) analysis for understanding the stress differences on endplates between PECS and flat-shaped endplate contact surface (FECS). Stiffness/yield strength were found to be 2127 ± 146 N/mm/8547 ± 1213 N for the compression test, 1158 ± 139 N/mm/ 2561 ± 114 N for the shear test, and 1.22 ± 0.32 Nm/deg/16.5 ± 0.58 Nm for the torque test. Some failure samples showed that fixation screws were fractured/loosened under the shear test. The endure limits were 1600 N, 350 N and 1.0 N*m under compression, shear and torsion cyclic load tests, respectively. The results of the static axial compression and static/dynamic compression-shear testing did not meet the acceptance criteria of ISO 23,089. The PECS with higher stiffness value showed that better subsidence resistance was achieved than FECS and was consistent with that the maximum stress value and distribution for the FECS were more harmful than those for the PECS models. This study demonstrated that mechanical testing is essential when assembling 3D-printed components with CNC-manufactured parts in multi-component medical implants, as mismatches in interface behavior may result in mechanical failure. The results of FE analysis and subsidence tests indicated that PECS can decrease stress concentration between the ECC and endplates to present better performance for subsidence resistance.

3D Printing in MedicineVol. 11(1)
National Yang Ming Chiao Tung University (TW), Tri-Service General Hospital Songshan Branch (TW), National Defense Medical Center (TW)
National Science and Technology Council
Openalex Percentile: Top 11%
Cervical and Thoracic Myelopathy
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.