Assessment of Blocking Contacts in Suppressing Polarization Effects in CsPbBr <sub>3</sub> Perovskite Detectors

The CsPbBr3 perovskite has garnered significant attention as a room-temperature semiconductor for hard radiation detection due to straightforward synthesis, scalable crystal growth, low cost, and excellent energy resolution. However, despite these advantages, at ambient temperature, CsPbBr3 (CLB) devices may experience performance deterioration and irreversible failure due to “polarization” induced by electromigration of ions to electrical connections on the device. In this study, we tested several contact materials and optimized their deposition techniques to assess the stability of high-performance CsPbBr3 γ-ray detectors. Metals, with low work functions (Ti, In, Sn, Sb, Pb, Bi, Al, and TiC) and high-work-function (Au or Pt) contacts, were used to form different Schottky junctions using vacuum thermal evaporation, electron-beam evaporation, and sputtering methods. These detectors were tested in intermittent and continuous modes to assess their stability. Among the tested detectors, the Bi/CLB/Pt electrode configuration demonstrated superior stability, operating effectively for 11 months under periodic testing and 16 days under continuous testing. In contrast, other configurations functioned only for a few months under intermittent conditions. Upon incorporating a ∼40 nm-thick TiC passivation layer on the anode side (Bi/TiC/CLB/Pt), the CLB device operated continuously for 36 days without degradation. In many cases, the failure mode of the devices was due to the degradation of the anode. The chemical changes in the fresh and deteriorated anodes were characterized using scanning electron microscopy and energy-dispersive X-ray spectroscopy.

Authors

Institutions

Publication Details

Journal
ACS Applied Electronic Materials
Published
2025-10-23
DOI
https://doi.org/10.1021/acsaelm.5c01611
Citations
1
Primary Topic
Perovskite Materials and Applications
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Blocking Contacts in Suppressing Polarization Effects in CsPbBr 3 Perovskite Detectors

Duck Young Chung, Khasim Saheb Bayikadi, Safdar Imam, Mercouri G. Kanatzidis et al.
1 citations
ACS Applied Electronic Materials
Perovskite Materials and Applications
0.73
article

Assessment of Blocking Contacts in Suppressing Polarization Effects in CsPbBr 3 Perovskite Detectors

Duck Young Chung, Khasim Saheb Bayikadi, Safdar Imam, Mercouri G. Kanatzidis, Mustafa Ünal, Indra Raj Pandey, Q.V. Phan, Sujita Karki
article en
1 citations

Abstract

The CsPbBr3 perovskite has garnered significant attention as a room-temperature semiconductor for hard radiation detection due to straightforward synthesis, scalable crystal growth, low cost, and excellent energy resolution. However, despite these advantages, at ambient temperature, CsPbBr3 (CLB) devices may experience performance deterioration and irreversible failure due to “polarization” induced by electromigration of ions to electrical connections on the device. In this study, we tested several contact materials and optimized their deposition techniques to assess the stability of high-performance CsPbBr3 γ-ray detectors. Metals, with low work functions (Ti, In, Sn, Sb, Pb, Bi, Al, and TiC) and high-work-function (Au or Pt) contacts, were used to form different Schottky junctions using vacuum thermal evaporation, electron-beam evaporation, and sputtering methods. These detectors were tested in intermittent and continuous modes to assess their stability. Among the tested detectors, the Bi/CLB/Pt electrode configuration demonstrated superior stability, operating effectively for 11 months under periodic testing and 16 days under continuous testing. In contrast, other configurations functioned only for a few months under intermittent conditions. Upon incorporating a ∼40 nm-thick TiC passivation layer on the anode side (Bi/TiC/CLB/Pt), the CLB device operated continuously for 36 days without degradation. In many cases, the failure mode of the devices was due to the degradation of the anode. The chemical changes in the fresh and deteriorated anodes were characterized using scanning electron microscopy and energy-dispersive X-ray spectroscopy.

ACS Applied Electronic MaterialsVol. 7(21)
Argonne National Laboratory (US), Division of Materials Science and Engineering (AU)
Openalex Percentile: Top 22%
Perovskite Materials and Applications
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.