Synthesis of Magnetic Azo‐Linked Covalent Organic Polymer for Rapid Extraction of β‐Agonists in Swine Urine Samples

The illegal use of β-agonists as feed additives can harm animal-derived food safety. In this study, a detection method for β-agonists in swine urine was established by the combination of azo-linked covalent organic polymer-miniaturized magnetic solid-phase extraction. The main factors that affect the extraction procedure were optimized. The designed adsorbent had good reusability, reproducibility, and stability. Under optimal conditions, the method achieved a good linear correlation coefficient (> 0.99) and a low detection limit (0.01 µg/L). The recoveries of the proposed method in swine urine samples for the simultaneous determination of β-agonists were in the range of 84.3%-99.4%, and the relative standard deviations were less than 6.5%.

Authors

Institutions

Publication Details

Journal
Journal of Separation Science
Published
2025-10-01
DOI
https://doi.org/10.1002/jssc.70302
Citations
1
Primary Topic
Pharmacological Effects and Assays
Type
article
Field-Weighted Citation Impact
1.19
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synthesis of Magnetic Azo‐Linked Covalent Organic Polymer for Rapid Extraction of β‐Agonists in Swine Urine Samples

Qie Gen Liao, Lijuan Yuan, Jianjun Xiang, Dawen Zhang
1 citations
Journal of Separation Science
Pharmacological Effects and Assays
1.19
article

Synthesis of Magnetic Azo‐Linked Covalent Organic Polymer for Rapid Extraction of β‐Agonists in Swine Urine Samples

Qie Gen Liao, Lijuan Yuan, Jianjun Xiang, Dawen Zhang
article en
1 citations

Abstract

The illegal use of β-agonists as feed additives can harm animal-derived food safety. In this study, a detection method for β-agonists in swine urine was established by the combination of azo-linked covalent organic polymer-miniaturized magnetic solid-phase extraction. The main factors that affect the extraction procedure were optimized. The designed adsorbent had good reusability, reproducibility, and stability. Under optimal conditions, the method achieved a good linear correlation coefficient (> 0.99) and a low detection limit (0.01 µg/L). The recoveries of the proposed method in swine urine samples for the simultaneous determination of β-agonists were in the range of 84.3%-99.4%, and the relative standard deviations were less than 6.5%.

Journal of Separation ScienceVol. 48(10)
Ministry of Agriculture and Rural Affairs (CN), Jiangxi Academy of Agricultural Sciences (CN), Jiangxi Agricultural University (CN)
Openalex Percentile: Top 19%
Pharmacological Effects and Assays
1.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Synthesis of Magnetic Azo‐Linked Covalent Organic Polymer for Rapid Extraction of β‐Agonists in Swine Urine Samples — Qie Gen Liao, Lijuan Yuan, et al. · Journal of Separation Science (2025) | TGRS Research Map | TGRS