Novel Two-Chamber Method for High-Precision TCR Determination of Current Shunts—Part II

This paper presents the experimental implementation and validation of the two-chamber method presented in Part I for the high-precision determination of the temperature coefficient of resistance (TCR) of current shunts. The two-chamber approach enables improved thermal isolation and independent temperature control of the reference and test shunts, which significantly reduces the measurement uncertainty. In this part, the complete experimental setup is described, including the thermoelectric temperature control, the current generation and the data acquisition system with synchronized high-resolution digital multimeters (DMMs). The experimental measurements were carried out for different resistance ratios ranging from 0.1 to 10. The results confirm the theoretical predictions and the uncertainty analysis from Part I. The influences of the stability of the current source, the temperature uniformity and the synchronization accuracy on the measurement results are evaluated. The two-chamber method shows high repeatability, ease of use and suitability for laboratory and interlaboratory tests, and thus represents a robust alternative to classical TCR determination methods.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-10-22
DOI
https://doi.org/10.3390/s25216513
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Two-Chamber Method for High-Precision TCR Determination of Current Shunts—Part II

Petar Mostarac, Alan Šala, Roman Malarić, Hrvoje Hegeduš
Sensors
Analytical Chemistry and Sensors
article

Novel Two-Chamber Method for High-Precision TCR Determination of Current Shunts—Part II

Petar Mostarac, Alan Šala, Roman Malarić, Hrvoje Hegeduš
article en

Abstract

This paper presents the experimental implementation and validation of the two-chamber method presented in Part I for the high-precision determination of the temperature coefficient of resistance (TCR) of current shunts. The two-chamber approach enables improved thermal isolation and independent temperature control of the reference and test shunts, which significantly reduces the measurement uncertainty. In this part, the complete experimental setup is described, including the thermoelectric temperature control, the current generation and the data acquisition system with synchronized high-resolution digital multimeters (DMMs). The experimental measurements were carried out for different resistance ratios ranging from 0.1 to 10. The results confirm the theoretical predictions and the uncertainty analysis from Part I. The influences of the stability of the current source, the temperature uniformity and the synchronization accuracy on the measurement results are evaluated. The two-chamber method shows high repeatability, ease of use and suitability for laboratory and interlaboratory tests, and thus represents a robust alternative to classical TCR determination methods.

SensorsVol. 25(21)
University of Zagreb (HR)
Openalex Percentile: Top 59%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Novel Two-Chamber Method for High-Precision TCR Determination of Current Shunts—Part II — Petar Mostarac, Alan Šala, et al. · Sensors (2025) | TGRS Research Map | TGRS