A novel pneumatic compression device Pneumasox®; a proof of principle

IntroductionThe gold standard treatment for Chronic Venous Disease (CVD) is compression therapy. Current types of compression therapy often lack properties like comfort and ease of use, which makes patient compliance challenging. Recently a new pneumatic compression therapy device was developed, called Pneumasox® (PSX). The device is based on Pascal's law, using air to create pressure. This could be an interesting addition to the current treatments.MethodsWe evaluated the pressure properties of the PSX. This was investigated by examining both the pressure inside the PSX and the interface pressure. For the primary outcome, the pressure was measured for three different settings (after first inflation, after 10 dorsiflexion movements, 2 min after the movements). This was separately investigated for the anatomical B1 and C point. As a secondary outcome, we investigated the reduction of the pressure after its application. All measurements were performed on a non-moving, dangling leg.ResultsThe average pressure in the PSX after the first inflation was 31 mm Hg. The average interface pressure was 33 mm Hg. Dorsiflexion movements initially resulted in a pressure drop of 14-16 mm Hg, but after 2 min the average pressures had increased to 27 mm Hg (PSX), 30 mm Hg (interface pressure, B1 point) and 31 mm Hg (interface pressure, C point). The average decrease in pressure after 30 min was about one-third of the initial pressure, with a peak during the first minute (6-7 mm Hg).ConclusionOur study suggests a promising role for the PSX in the treatment of CVD and especially for venous leg ulcers in an outpatient setting. However, further experiments are necessary to investigate the effects during daily activities. Considering the fact that the reduction is highest during the first minute, we suggest that repressurizing should take place after 1 min.

Authors

Institutions

Publication Details

Journal
Phlebology The Journal of Venous Disease
Published
2025-10-22
DOI
https://doi.org/10.1177/02683555251391859
Primary Topic
Diagnosis and Treatment of Venous Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel pneumatic compression device Pneumasox®; a proof of principle

Tim Wentel, Marcel W. Bekkenk, Kees-Peter de Roos, Martino Neumann et al.
Phlebology The Journal of Venous Disease
Diagnosis and Treatment of Venous Diseases
article

A novel pneumatic compression device Pneumasox®; a proof of principle

Tim Wentel, Marcel W. Bekkenk, Kees-Peter de Roos, Martino Neumann, Kelley van der Meer
article en

Abstract

IntroductionThe gold standard treatment for Chronic Venous Disease (CVD) is compression therapy. Current types of compression therapy often lack properties like comfort and ease of use, which makes patient compliance challenging. Recently a new pneumatic compression therapy device was developed, called Pneumasox® (PSX). The device is based on Pascal's law, using air to create pressure. This could be an interesting addition to the current treatments.MethodsWe evaluated the pressure properties of the PSX. This was investigated by examining both the pressure inside the PSX and the interface pressure. For the primary outcome, the pressure was measured for three different settings (after first inflation, after 10 dorsiflexion movements, 2 min after the movements). This was separately investigated for the anatomical B1 and C point. As a secondary outcome, we investigated the reduction of the pressure after its application. All measurements were performed on a non-moving, dangling leg.ResultsThe average pressure in the PSX after the first inflation was 31 mm Hg. The average interface pressure was 33 mm Hg. Dorsiflexion movements initially resulted in a pressure drop of 14-16 mm Hg, but after 2 min the average pressures had increased to 27 mm Hg (PSX), 30 mm Hg (interface pressure, B1 point) and 31 mm Hg (interface pressure, C point). The average decrease in pressure after 30 min was about one-third of the initial pressure, with a peak during the first minute (6-7 mm Hg).ConclusionOur study suggests a promising role for the PSX in the treatment of CVD and especially for venous leg ulcers in an outpatient setting. However, further experiments are necessary to investigate the effects during daily activities. Considering the fact that the reduction is highest during the first minute, we suggest that repressurizing should take place after 1 min.

Phlebology The Journal of Venous Disease
Erasmus MC (NL), Kliniek ViaSana (NL), Amsterdam University Medical Centers (NL), Erasmus University Rotterdam (NL)
Openalex Percentile: Top 52%
Diagnosis and Treatment of Venous Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.