Rethinking the Bland-Altman plot when quantifying virtual coronary physiology

Angiography-derived, or "virtual" fractional flow reserve (vFFR) is beginning to replace invasive assessment in some catheterisation laboratories. Despite its incorporation into clinical guidelines, recent clinical outcomes data have cast doubt over its effectiveness relative to invasive assessment. These somewhat unexpected trial results are underpinned by poorer than anticipated agreement between invasive and vFFR. In particular, the widespread use of traditional Bland-Altman analysis fails to account for the phenomenon of worsening agreement at lower FFR values which hinders comparison between studies. We propose a novel approach using quantile regression to derive overall bias and limits of agreement (LOA) to better characterise agreement across the spectrum of coronary disease. This new method may improve understanding of optimal vFFR clinical applications and addresses common statistical deficiencies in current validation practices.

Authors

Institutions

Publication Details

Journal
Frontiers in Cardiovascular Medicine
Published
2025-10-23
DOI
https://doi.org/10.3389/fcvm.2025.1687923
Citations
1
Primary Topic
Cardiovascular Health and Disease Prevention
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rethinking the Bland-Altman plot when quantifying virtual coronary physiology

Daniel J. Taylor, Ian Halliday, Julian Gunn, Harry Saxton et al.
1 citations
Frontiers in Cardiovascular Medicine
Cardiovascular Health and Disease Prevention
1.39
article

Rethinking the Bland-Altman plot when quantifying virtual coronary physiology

Daniel J. Taylor, Ian Halliday, Julian Gunn, Harry Saxton, Paul Morris
article en
1 citations

Abstract

Angiography-derived, or "virtual" fractional flow reserve (vFFR) is beginning to replace invasive assessment in some catheterisation laboratories. Despite its incorporation into clinical guidelines, recent clinical outcomes data have cast doubt over its effectiveness relative to invasive assessment. These somewhat unexpected trial results are underpinned by poorer than anticipated agreement between invasive and vFFR. In particular, the widespread use of traditional Bland-Altman analysis fails to account for the phenomenon of worsening agreement at lower FFR values which hinders comparison between studies. We propose a novel approach using quantile regression to derive overall bias and limits of agreement (LOA) to better characterise agreement across the spectrum of coronary disease. This new method may improve understanding of optimal vFFR clinical applications and addresses common statistical deficiencies in current validation practices.

Frontiers in Cardiovascular MedicineVol. 12
Sheffield Teaching Hospitals NHS Foundation Trust (GB), Insigneo (GB), University of Sheffield (GB)
Openalex Percentile: Top 14%
Cardiovascular Health and Disease Prevention
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.