Environmental acoustics: Comparison of noise exposure measurements recorded in dosimeters and sound level meters

A methodological development is proposed to compare the results of measurements of the equivalent level of noise exposure (ambient sound) and SEL in urban areas near traffic routes obtained in the conventional way by using a fixed-point sound level meter and mobile noise dosimeters with respect to the location of the sound level meter. Class I calibrated equipment is used for the sound level meter and Class II for the dosimeter. Comparisons are made by maintaining a fixed point location for the sound level meter and using 1 dosimeter for measurements in different media moving with reference to the fixed point. The investigation is ongoing. To simulate the measured scenarios a mathematical model, from the Department of Mechanical and Energy Engineering of the Miguel Hernandez University of Elche (Spain), is used to compare measured results against model results. The field values are used to calibrate the model validating it for use when it is necessary to have exposure values at different heights. The first results show an appreciable difference between noise exposure results in the conventional way, for different environments in urban areas close to traffic routes, with the highest incidence on pedestrians.

Authors

Institutions

Publication Details

Journal
NOISE-CON proceedings
Published
2025-10-22
DOI
https://doi.org/10.3397/in_2025_1072432
Primary Topic
Noise Effects and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Environmental acoustics: Comparison of noise exposure measurements recorded in dosimeters and sound level meters

Alice Elizabeth González, Héctor Campello Vicente, LUIS MARISQUIRENA
NOISE-CON proceedings
Noise Effects and Management
article

Environmental acoustics: Comparison of noise exposure measurements recorded in dosimeters and sound level meters

Alice Elizabeth González, Héctor Campello Vicente, LUIS MARISQUIRENA
article en

Abstract

A methodological development is proposed to compare the results of measurements of the equivalent level of noise exposure (ambient sound) and SEL in urban areas near traffic routes obtained in the conventional way by using a fixed-point sound level meter and mobile noise dosimeters with respect to the location of the sound level meter. Class I calibrated equipment is used for the sound level meter and Class II for the dosimeter. Comparisons are made by maintaining a fixed point location for the sound level meter and using 1 dosimeter for measurements in different media moving with reference to the fixed point. The investigation is ongoing. To simulate the measured scenarios a mathematical model, from the Department of Mechanical and Energy Engineering of the Miguel Hernandez University of Elche (Spain), is used to compare measured results against model results. The field values are used to calibrate the model validating it for use when it is necessary to have exposure values at different heights. The first results show an appreciable difference between noise exposure results in the conventional way, for different environments in urban areas close to traffic routes, with the highest incidence on pedestrians.

NOISE-CON proceedingsVol. 272(4)
Universitat de Miguel Hernández d'Elx (ES), Universidad de la República de Uruguay (UY), Universidad La República (CL)
Openalex Percentile: Top 59%
Noise Effects and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.