Aeroacoustic Wind Tunnel Studies with Suprema10K a MEMS Microphone Array with 12.000 sensors

The signal-to-noise ratio of phased arrays can be improved by increasing the number of samples (the number of microphones or the number of averages). Increasing the array sized also allows the direct measurement of the source directivity, without moving the array. In this paper we present a module microphone array with data acquisition system, consisting of 1 m x 2m panels with 800 MEMS microphones, each. This modular architecture allows the time-synchronized measurement of an arbitrary number of panels and thus, aperture size and total number of sensors This architecture was used as a 7200 MEMS microphone array with a 6 m x 3 m aperture on an open wind tunnel airframe test at DNW-NWB. A second test used 12.000 MEMS microphones with a 6 m x 5 m aperture on an open wind tunnel test at DNW-LLF Sources identification directivity measurements will be shown. Additional far-field microphones and a classical analog array are employed to validate the beamforming results and directivity analysis.

Authors

Institutions

Publication Details

Journal
NOISE-CON proceedings
Published
2025-10-22
DOI
https://doi.org/10.3397/in_2025_1074291
Primary Topic
Aerodynamics and Acoustics in Jet Flows
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aeroacoustic Wind Tunnel Studies with Suprema10K a MEMS Microphone Array with 12.000 sensors

Reinhard Geisler, Florian Philipp, Daniel Ernst, Thomas Ahlefeldt et al.
NOISE-CON proceedings
Aerodynamics and Acoustics in Jet Flows
article

Aeroacoustic Wind Tunnel Studies with Suprema10K a MEMS Microphone Array with 12.000 sensors

Reinhard Geisler, Florian Philipp, Daniel Ernst, Thomas Ahlefeldt, Armin Goudarzi, Carsten Spehr
article en

Abstract

The signal-to-noise ratio of phased arrays can be improved by increasing the number of samples (the number of microphones or the number of averages). Increasing the array sized also allows the direct measurement of the source directivity, without moving the array. In this paper we present a module microphone array with data acquisition system, consisting of 1 m x 2m panels with 800 MEMS microphones, each. This modular architecture allows the time-synchronized measurement of an arbitrary number of panels and thus, aperture size and total number of sensors This architecture was used as a 7200 MEMS microphone array with a 6 m x 3 m aperture on an open wind tunnel airframe test at DNW-NWB. A second test used 12.000 MEMS microphones with a 6 m x 5 m aperture on an open wind tunnel test at DNW-LLF Sources identification directivity measurements will be shown. Additional far-field microphones and a classical analog array are employed to validate the beamforming results and directivity analysis.

NOISE-CON proceedingsVol. 272(3)
Deutsches Zentrum für Luft- und Raumfahrt e. V. (DLR) (DE)
Openalex Percentile: Top 59%
Aerodynamics and Acoustics in Jet Flows
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Aeroacoustic Wind Tunnel Studies with Suprema10K a MEMS Microphone Array with 12.000 sensors — Reinhard Geisler, Florian Philipp, et al. · NOISE-CON proceedings (2025) | TGRS Research Map | TGRS