Proposed values of early decay time aiming the student´s satisfaction with the classrooms acoustic quality

A new range of values for the early decay time (EDT) given in 1/1 octave band is proposed. With the objective of studying an acceptable EDT range from the point of view of the students satisfaction with the acoustic quality of classrooms, acoustic measurements were carried out in classrooms of Brazilian schools located in the metropolitan area of Greater São Paulo. Questionnaires were administered to the students of those classrooms in which the measurements took place in order to assess the occupants' satisfaction with the rooms. The results of this research indicate that the classical limits are more conservative, except when compared to the auditorium limits of ISO 3382-1 (2009).

Authors

Institutions

Publication Details

Journal
NOISE-CON proceedings
Published
2025-10-22
DOI
https://doi.org/10.3397/in_2025_1074292
Primary Topic
Noise Effects and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proposed values of early decay time aiming the student´s satisfaction with the classrooms acoustic quality

Rosária Ono, Cristina Yukari Kawakita Ikeda, Fúlvio Vittorino
NOISE-CON proceedings
Noise Effects and Management
article

Proposed values of early decay time aiming the student´s satisfaction with the classrooms acoustic quality

Rosária Ono, Cristina Yukari Kawakita Ikeda, Fúlvio Vittorino
article en

Abstract

A new range of values for the early decay time (EDT) given in 1/1 octave band is proposed. With the objective of studying an acceptable EDT range from the point of view of the students satisfaction with the acoustic quality of classrooms, acoustic measurements were carried out in classrooms of Brazilian schools located in the metropolitan area of Greater São Paulo. Questionnaires were administered to the students of those classrooms in which the measurements took place in order to assess the occupants' satisfaction with the rooms. The results of this research indicate that the classical limits are more conservative, except when compared to the auditorium limits of ISO 3382-1 (2009).

NOISE-CON proceedingsVol. 272(3)
Industry and Parliament Trust (GB), Hospital Universitário da Universidade de São Paulo (BR), Instituto de Pesquisas Tecnológicas (BR)
Openalex Percentile: Top 59%
Noise Effects and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.