Fenestrated Endovascular Graft Implantation for Treatment of Juxtarenal Abdominal Aortic Aneurysm: Multicenter Experience in China

ABSTRACT Background Abdominal aortic aneurysms (AAAs) are a common vascular disease, and juxtarenal abdominal aortic aneurysms (JRAAs) pose significant challenges for traditional open surgical repair because of their complex anatomical location. In recent years, endovascular aneurysm repair (EVAR) has emerged as a key treatment option for JRAAs, but data on its application in Chinese patient populations remain limited. This study was conducted to evaluate the safety and efficacy of the Zenith fenestrated endovascular graft in treating JRAAs in Chinese patient population. Methods Clinical data from 30 consecutive patients (86.7% men; mean age, 68 ± 8 years) treated for JRAAs with the Zenith device at 9 institutions in China between 21 February 2011 and 31 August 2014 were retrospectively analyzed. Postoperative follow‐up included clinical examination, abdominal duplex ultrasound, and computed tomography at hospital discharge, 3, 6, and 12 months, and annually thereafter. Results The procedure achieved a 100% technical success rate, with 5 large fenestrations cannulated to the superior mesenteric artery and 52 small fenestrations targeting the renal arteries. Steep angulation made cannulation difficult in five patients. Over a mean follow‐up period of 42 ± 18 months (range, 8–56 months), outcomes included three deaths, none related to aneurysmal rupture or conversion; one dissection at the edge of a left renal covered stent secondary to arterial rupture during implantation; right renal artery migration due to preoperative hematoma compression in one patient; and among 55 targeted renal arteries, two occlusions and five stenoses across four patients (13.3%). Secondary interventions were required in seven patients (23.3%) for Type II ( n = 6) and Type I ( n = 1) endoleaks. Conclusions Endovascular repair of JRAAs using the Zenith device appears to be safe and effective in selected patients treated at experienced centers, with low associated mortality and morbidity. However, long‐term data on device integrity and branch vessel patency are needed.

Authors

Institutions

Publication Details

Journal
Medicine Advances
Published
2025-10-22
DOI
https://doi.org/10.1002/med4.70031
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fenestrated Endovascular Graft Implantation for Treatment of Juxtarenal Abdominal Aortic Aneurysm: Multicenter Experience in China

Xin Jia, Wei Guo, Lijun Wang, Jiang Xiong et al.
Medicine Advances
Aortic aneurysm repair treatments
article

Fenestrated Endovascular Graft Implantation for Treatment of Juxtarenal Abdominal Aortic Aneurysm: Multicenter Experience in China

Xin Jia, Wei Guo, Lijun Wang, Jiang Xiong, Xiaoping Liu, Siqi Zhang, Hongpeng Zhang, Hongyi Huang, Xiaohui Ma, Kuan Hu
article en

Abstract

ABSTRACT Background Abdominal aortic aneurysms (AAAs) are a common vascular disease, and juxtarenal abdominal aortic aneurysms (JRAAs) pose significant challenges for traditional open surgical repair because of their complex anatomical location. In recent years, endovascular aneurysm repair (EVAR) has emerged as a key treatment option for JRAAs, but data on its application in Chinese patient populations remain limited. This study was conducted to evaluate the safety and efficacy of the Zenith fenestrated endovascular graft in treating JRAAs in Chinese patient population. Methods Clinical data from 30 consecutive patients (86.7% men; mean age, 68 ± 8 years) treated for JRAAs with the Zenith device at 9 institutions in China between 21 February 2011 and 31 August 2014 were retrospectively analyzed. Postoperative follow‐up included clinical examination, abdominal duplex ultrasound, and computed tomography at hospital discharge, 3, 6, and 12 months, and annually thereafter. Results The procedure achieved a 100% technical success rate, with 5 large fenestrations cannulated to the superior mesenteric artery and 52 small fenestrations targeting the renal arteries. Steep angulation made cannulation difficult in five patients. Over a mean follow‐up period of 42 ± 18 months (range, 8–56 months), outcomes included three deaths, none related to aneurysmal rupture or conversion; one dissection at the edge of a left renal covered stent secondary to arterial rupture during implantation; right renal artery migration due to preoperative hematoma compression in one patient; and among 55 targeted renal arteries, two occlusions and five stenoses across four patients (13.3%). Secondary interventions were required in seven patients (23.3%) for Type II ( n = 6) and Type I ( n = 1) endoleaks. Conclusions Endovascular repair of JRAAs using the Zenith device appears to be safe and effective in selected patients treated at experienced centers, with low associated mortality and morbidity. However, long‐term data on device integrity and branch vessel patency are needed.

Medicine AdvancesVol. 3(4)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Chinese PLA General Hospital (CN)
Openalex Percentile: Top 57%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.