SAT-625 Democratization of Glycemic Outcomes in People with Type 1 Diabetes (T1D) using the MiniMed™ 780G System of Automated Insulin Delivery (AID)

Abstract Disclosure: R.A. Vigersky: Medtronic Minimed. T. Cordero: Medtronic Diabetes. A. Arrieta: Medtronic Diabetes. M. Liu: Medtronic Diabetes. B. Grosman: Medtronic Diabetes. J. Shin: Medtronic Diabetes. Introduction: AID therapy is recognized as the standard of care for managing glycemia in children and adults with T1D by professional societies and health ministries, globally (ADA- 2025. doi:10.2337/dc25-S007; ISPAD- 2024. doi:10.1159/000543034; UK NICE- https://www.nice.org.uk/guidance/TA943). There are, currently, six commercialized AID therapies (MiniMed™ 780G [MM780G], CamAPS FX, Insulet Omnipod™ 5, Tandem Control™ IQ, Beta Bionics iLet™ and Diabeloop DBLG1 systems) in various countries each having different algorithmic approaches to managing glucose. Real-world data demonstrating the effectiveness of these systems comes from single centers, single countries, or multiple countries within a region. We hypothesized that the MM780G, an advanced hybrid closed-loop system with an algorithm that provides automated basal and correction insulin doses up to every 5 minutes and several glucose target (GT) and active insulin time (AIT) settings, could mitigate regional, cultural and dietary differences in glycemic outcomes in people with T1D and provide similar time in range (TIR, 70-180mg/dL), time above range (TAR 180mg/dL), time below range (TBR 70mg/dL) and glucose management indicator (GMI) and percentage of users reaching international consensus glycemic targets, across the globe. We also studied whether using the recommended optimal settings (ROS, 100mg/dL GT and 2hrs AIT ≥95% of the time) further narrows those differences. Methods: CareLink™ data of consenting MM780G users (any age, with ≥10 days of CGM use) that were uploaded since commercial availability in the following regions; Europe, Middle East and Africa (EMEA) (median 356 days of use), United States (US) (174.7 days), Asia-Pacific (APAC) (245 days), Latin America (LATAM) (213 days) and Canada (CAN) (261.9 days) were de-identified, aggregated and analyzed. The number of users in each region was >10,000 (>8,000 for CAN). Results: During overall settings use, mean %TIR and GMI were 72.1% and 6.9% (EMEA), 73.1% and 7.0% (US), 70.7% and 7.0% (APAC), and 74.0% and 6.8% (LATAM) and 72.6% and 7.0% (CAN). For all regions, mean %TAR was 23-27%, %TBR was ≤2.6% and 40-50% met consensus-recommended targets for all four metrics. In the 10-30% using the ROS, the %TIR and GMI were 77.6% and 6.8% in the EMEA, 78.0% and 6.8% in US, 76.3% and 6.8% in APAC, 78.1% and 6.7% in LATAM, and 78.3% and 6.7% in CAN. Mean %TAR was reduced to <21% and %TBR was ≤2.6% across regions. ROS use allowed 60-70% of users to meet targets. The trends in glycemic outcomes and rates meeting glycemic targets were observed for a majority of countries within the regions. Conclusion: The data show similar glycemic outcomes in real-world MM780G users across the world suggesting the algorithmic approach employed by the MM780G may be democratizing the management of T1D across cultures. The use of ROS increased the percentage reaching consensus-recommended targets by ∼20%. Presentation: Saturday, July 12, 2025

Authors

Institutions

Publication Details

Journal
Journal of the Endocrine Society
Published
2025-10-01
DOI
https://doi.org/10.1210/jendso/bvaf149.1151
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SAT-625 Democratization of Glycemic Outcomes in People with Type 1 Diabetes (T1D) using the MiniMed™ 780G System of Automated Insulin Delivery (AID)

Robert Alan Vigersky, Benyamin Grosman, John Shin, Arcelia Arrieta et al.
Journal of the Endocrine Society
Diabetes Management and Research
article

SAT-625 Democratization of Glycemic Outcomes in People with Type 1 Diabetes (T1D) using the MiniMed™ 780G System of Automated Insulin Delivery (AID)

Robert Alan Vigersky, Benyamin Grosman, John Shin, Arcelia Arrieta, Toni L. Cordero, Margaret Liu
article en

Abstract

Abstract Disclosure: R.A. Vigersky: Medtronic Minimed. T. Cordero: Medtronic Diabetes. A. Arrieta: Medtronic Diabetes. M. Liu: Medtronic Diabetes. B. Grosman: Medtronic Diabetes. J. Shin: Medtronic Diabetes. Introduction: AID therapy is recognized as the standard of care for managing glycemia in children and adults with T1D by professional societies and health ministries, globally (ADA- 2025. doi:10.2337/dc25-S007; ISPAD- 2024. doi:10.1159/000543034; UK NICE- https://www.nice.org.uk/guidance/TA943). There are, currently, six commercialized AID therapies (MiniMed™ 780G [MM780G], CamAPS FX, Insulet Omnipod™ 5, Tandem Control™ IQ, Beta Bionics iLet™ and Diabeloop DBLG1 systems) in various countries each having different algorithmic approaches to managing glucose. Real-world data demonstrating the effectiveness of these systems comes from single centers, single countries, or multiple countries within a region. We hypothesized that the MM780G, an advanced hybrid closed-loop system with an algorithm that provides automated basal and correction insulin doses up to every 5 minutes and several glucose target (GT) and active insulin time (AIT) settings, could mitigate regional, cultural and dietary differences in glycemic outcomes in people with T1D and provide similar time in range (TIR, 70-180mg/dL), time above range (TAR 180mg/dL), time below range (TBR 70mg/dL) and glucose management indicator (GMI) and percentage of users reaching international consensus glycemic targets, across the globe. We also studied whether using the recommended optimal settings (ROS, 100mg/dL GT and 2hrs AIT ≥95% of the time) further narrows those differences. Methods: CareLink™ data of consenting MM780G users (any age, with ≥10 days of CGM use) that were uploaded since commercial availability in the following regions; Europe, Middle East and Africa (EMEA) (median 356 days of use), United States (US) (174.7 days), Asia-Pacific (APAC) (245 days), Latin America (LATAM) (213 days) and Canada (CAN) (261.9 days) were de-identified, aggregated and analyzed. The number of users in each region was >10,000 (>8,000 for CAN). Results: During overall settings use, mean %TIR and GMI were 72.1% and 6.9% (EMEA), 73.1% and 7.0% (US), 70.7% and 7.0% (APAC), and 74.0% and 6.8% (LATAM) and 72.6% and 7.0% (CAN). For all regions, mean %TAR was 23-27%, %TBR was ≤2.6% and 40-50% met consensus-recommended targets for all four metrics. In the 10-30% using the ROS, the %TIR and GMI were 77.6% and 6.8% in the EMEA, 78.0% and 6.8% in US, 76.3% and 6.8% in APAC, 78.1% and 6.7% in LATAM, and 78.3% and 6.7% in CAN. Mean %TAR was reduced to <21% and %TBR was ≤2.6% across regions. ROS use allowed 60-70% of users to meet targets. The trends in glycemic outcomes and rates meeting glycemic targets were observed for a majority of countries within the regions. Conclusion: The data show similar glycemic outcomes in real-world MM780G users across the world suggesting the algorithmic approach employed by the MM780G may be democratizing the management of T1D across cultures. The use of ROS increased the percentage reaching consensus-recommended targets by ∼20%. Presentation: Saturday, July 12, 2025

Journal of the Endocrine SocietyVol. 9(Supplement_1)
Medtronic (Ireland) (IE), Medtronic (United States) (US)
Openalex Percentile: Top 59%
Diabetes Management and Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.