SUN-251 Highly Sensitive ELISA System Enables Direct Detection of C-Type Natriuretic Peptide-53 in Plasma Without Extraction

Abstract Disclosure: D. Kosugi: None. N. Minamino: None. D. Taura: None. M. Makoto: None. M. Ohta: None. K. Nakao: None. Background and aim: Mammalian natriuretic peptide (NP) family is composed of A-type (Atrial), B-type (Brain) and C-type NP; ANP, BNP, and CNP. CNP is widely distributed in the central and peripheral tissues. CNP induces endochondral ossification, vasorelaxation, antifibrosis, and so forth as a local regulator, and its analog, vosoritide, is used for the therapy for achondroplasia. However, the clinical significance of CNP has not yet been established, mainly due to lack of methods sensitive enough for measuring plasma CNP without extraction. Although plasma CNP levels in normal subjects are presumed to be at 0.1-0.5 pM, many researchers have reported far higher CNP levels. In the present study, we have undertaken development of sandwich chemiluminescent ELISA (CLEIA) for CNP-53, the major circulating molecular form of CNP in plasma. Methods: Monoclonal antibodies targeting the ring portion and N-terminal region of CNP-53 were generated by immunizing rats or mice with respective peptide-KLH conjugates, followed by cloning and selection. Antibody #26-7 recognizing the N-terminal region was biotinylated, fixed on the avidin plate, and used for capture antibody. Antibody #47-22 recognizing the ring portion was used for the detection antibody after labeling with alkaline phosphatase, where CDP-star/Emerald II was used as a substrate. Immunoreactive(ir) CNP-53 concentrations in plasma from healthy humans and Wistar Kyoto rats were measured. Results: The detection and quantitation limit of the developed CLEIA was 0.015pM and 0.041pM, respectively, and CNP-53 was measurable up to 250pM. This CLEIA showed equivalent recognition of mammalian CNP-53, including human and rat CNP-53, without cross-reactivity to CNP-22, ANP, BNP, or other related bioactive peptides, except for equal recognition of proCNP and CNP-53. In this CLEIA, plasma samples were measured after four-fold dilution and standard curves were generated with peptide-free-plasma. Plasma levels of irCNP-53 in healthy human subjects were 0.18±0.06 pM, and those in Wistar Kyoto rats were 0.24±0.02 pM. Further studies on plasma irCNP-53 from disease model rats and patients are ongoing in our laboratory. Conclusion: The newly developed CLEIA for CNP-53 demonstrated superior sensitivity and quantitation capabilities, allowing for direct and highly accurate measurement of plasma irCNP-53 concentrations. This method provides a more reliable and reproducible approach than previously reported assays. Utilizing this CLEIA, more detailed physiological and pathophysiological changes of plasma CNP will be elucidated in near future. Presentation: Sunday, July 13, 2025

Authors

Institutions

Publication Details

Journal
Journal of the Endocrine Society
Published
2025-10-01
DOI
https://doi.org/10.1210/jendso/bvaf149.868
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SUN-251 Highly Sensitive ELISA System Enables Direct Detection of C-Type Natriuretic Peptide-53 in Plasma Without Extraction

Makoto Matsuyama, Naoto Minamino, Mitsuhiro Ohta, Daisuke Kosugi et al.
Journal of the Endocrine Society
Nuclear Physics and Applications
article

SUN-251 Highly Sensitive ELISA System Enables Direct Detection of C-Type Natriuretic Peptide-53 in Plasma Without Extraction

Makoto Matsuyama, Naoto Minamino, Mitsuhiro Ohta, Daisuke Kosugi, Daisuke Taura, Kazuwa Nakao
article en

Abstract

Abstract Disclosure: D. Kosugi: None. N. Minamino: None. D. Taura: None. M. Makoto: None. M. Ohta: None. K. Nakao: None. Background and aim: Mammalian natriuretic peptide (NP) family is composed of A-type (Atrial), B-type (Brain) and C-type NP; ANP, BNP, and CNP. CNP is widely distributed in the central and peripheral tissues. CNP induces endochondral ossification, vasorelaxation, antifibrosis, and so forth as a local regulator, and its analog, vosoritide, is used for the therapy for achondroplasia. However, the clinical significance of CNP has not yet been established, mainly due to lack of methods sensitive enough for measuring plasma CNP without extraction. Although plasma CNP levels in normal subjects are presumed to be at 0.1-0.5 pM, many researchers have reported far higher CNP levels. In the present study, we have undertaken development of sandwich chemiluminescent ELISA (CLEIA) for CNP-53, the major circulating molecular form of CNP in plasma. Methods: Monoclonal antibodies targeting the ring portion and N-terminal region of CNP-53 were generated by immunizing rats or mice with respective peptide-KLH conjugates, followed by cloning and selection. Antibody #26-7 recognizing the N-terminal region was biotinylated, fixed on the avidin plate, and used for capture antibody. Antibody #47-22 recognizing the ring portion was used for the detection antibody after labeling with alkaline phosphatase, where CDP-star/Emerald II was used as a substrate. Immunoreactive(ir) CNP-53 concentrations in plasma from healthy humans and Wistar Kyoto rats were measured. Results: The detection and quantitation limit of the developed CLEIA was 0.015pM and 0.041pM, respectively, and CNP-53 was measurable up to 250pM. This CLEIA showed equivalent recognition of mammalian CNP-53, including human and rat CNP-53, without cross-reactivity to CNP-22, ANP, BNP, or other related bioactive peptides, except for equal recognition of proCNP and CNP-53. In this CLEIA, plasma samples were measured after four-fold dilution and standard curves were generated with peptide-free-plasma. Plasma levels of irCNP-53 in healthy human subjects were 0.18±0.06 pM, and those in Wistar Kyoto rats were 0.24±0.02 pM. Further studies on plasma irCNP-53 from disease model rats and patients are ongoing in our laboratory. Conclusion: The newly developed CLEIA for CNP-53 demonstrated superior sensitivity and quantitation capabilities, allowing for direct and highly accurate measurement of plasma irCNP-53 concentrations. This method provides a more reliable and reproducible approach than previously reported assays. Utilizing this CLEIA, more detailed physiological and pathophysiological changes of plasma CNP will be elucidated in near future. Presentation: Sunday, July 13, 2025

Journal of the Endocrine SocietyVol. 9(Supplement_1)
Kyoto University (JP), Kyoto College of Medical Science (JP), National Cerebral and Cardiovascular Center (JP), Research Institute for Production Development (JP), Shigei Medical Research Institute (JP), Protein Research Foundation (JP)
Openalex Percentile: Top 60%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.