Amperometric biosensors: Why might the response show a logarithmic dependence on analyte concentration?

Amperometric biosensors of different designs are often reported as having a logarithmic dependency on the target concentration. This paper provides a physicochemical basis for this behaviour if the adsorption of the analyte follows the Temkin Adsorption Isotherm over the range of concentrations of interest either by directly controlling the amount adsorbed or indirectly via the effect on the electrochemical rate constant. • Logarithmic biosensor response best-explained by Temkin adsorption isotherm. • Temkin model accounts for surface heterogeneity and lateral interactions. • Provides physicochemical basis for logarithmic calibration in amperometry. • Enhances reliability of biosensor design, calibration, and detection limits.

Authors

Institutions

Publication Details

Journal
Electrochemistry Communications
Published
2025-10-23
DOI
https://doi.org/10.1016/j.elecom.2025.108064
Citations
1
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Amperometric biosensors: Why might the response show a logarithmic dependence on analyte concentration?

Stanislav V. Sokolov, Morgan P. Milner, Richard G. Compton
1 citations
Electrochemistry Communications
Advanced biosensing and bioanalysis techniques
0.81
article

Amperometric biosensors: Why might the response show a logarithmic dependence on analyte concentration?

Stanislav V. Sokolov, Morgan P. Milner, Richard G. Compton
article en
1 citations

Abstract

Amperometric biosensors of different designs are often reported as having a logarithmic dependency on the target concentration. This paper provides a physicochemical basis for this behaviour if the adsorption of the analyte follows the Temkin Adsorption Isotherm over the range of concentrations of interest either by directly controlling the amount adsorbed or indirectly via the effect on the electrochemical rate constant. • Logarithmic biosensor response best-explained by Temkin adsorption isotherm. • Temkin model accounts for surface heterogeneity and lateral interactions. • Provides physicochemical basis for logarithmic calibration in amperometry. • Enhances reliability of biosensor design, calibration, and detection limits.

Electrochemistry CommunicationsVol. 181
University of Oxford (GB), St. John's College (US)
Openalex Percentile: Top 22%
Advanced biosensing and bioanalysis techniques
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.