MON-691 Oral Delivery Of A Bispecific GLP-1/GLP-2 Receptor Agonist (PG-102) Via A Robotic Pill (RT-114) Achieves Bioequivalence To Subcutaneous Injection In Canines

Abstract Disclosure: A. Dasari: Rani Therapeutics. A. Dhalla: Rani Therapeutics. L. Fung: Rani Therapeutics. M. Hashim: Rani Therapeutics. K. Horlen: ; Rani Therapeutics. K. Kaminskaya: Rani Therapeutics. H. Kennedy: Rani Therapeutics. H. Kim: ProGen. J. Kim: ProGen. J. Kim: ProGen. S. Kim: ProGen. S. Lee: ProGen. D. Mohan: Rani Therapeutics. N. Patel: Rani Therapeutics. K. Song: ProGen. A. Toledo Vo: Rani Therapeutics. A. Yamaguchi: Rani Therapeutics. S. Yang: ProGen. PG-102 is a novel, long-acting bispecific agonist composed of GLP-1 and GLP-2 peptides fused to a central Fc domain. With a favorable safety profile, PG-102 is currently in Phase 2 trials for obesity and type 2 diabetes. As with most incretin mimetics, PG-102 requires injections which can lead to patient discomfort, reduced acceptance, and suboptimal adherence to therapy. To address this challenge, we have developed RT-114, an orally ingestible robotic pill which delivers PG-102 transenterically upon reaching the small intestine. RT-114 is being developed for the treatment of obesity. This nonclinical study was designed to compare the oral delivery of PG-102 via RT-114 with a subcutaneous (SC) injection of PG-102. Sixteen healthy canines were randomized to receive a single 12mg dose of PG-102 either via SC injection (N=6) or orally via RT-114 (N=10). Over a 14-day period, pharmacokinetics (PK; measured as serum drug concentrations by ELISA), pharmacodynamic (PD) outcomes (food intake and body weight), as well as safety, tolerability, and delivery reliability were evaluated. RT-114 was well tolerated and demonstrated high drug delivery reliability achieving systemic drug exposure in 90% (9/10) of the animals. Crucially, PK analysis showed that oral delivery via RT-114 achieved bioequivalence with SC injection, exhibiting comparable serum-drug profiles and 111% average bioavailability relative to SC. Consistent with PK findings, both delivery methods resulted in the same average peak weight loss of 6.7%. Notably, the RT-114 group exhibited less variability in weight loss response compared to the SC group, as indicated by a lower standard deviation (± 1.4% vs ± 5.4%), demonstrating consistent dosing accuracy and suggesting potentially more predictable effects with oral delivery. PK-PD correlation analysis demonstrated a clear positive association between serum PG-102 levels and reduced food intake, consistent with the drug’s expected mechanism of action. Importantly, allometric modeling indicated strong concordance between the canine SC PK data and published human SC PK data, supporting the potential translatability of these RT-114 findings to humans. In summary, this nonclinical study demonstrated that the RT-114 oral robotic pill successfully delivered the bispecific GLP-1/GLP-2 receptor agonist PG-102 to achieve both PK and PD bioequivalence to SC injection. By offering a potentially more convenient alternative to SC injections, RT-114 holds promise for improving patient acceptance and long-term adherence. Moreover, targeted intestinal delivery via RT-114 may better mimic physiologic incretin release, potentially enhancing gut-brain pathway engagement. Collectively, these compelling nonclinical results provide a robust rationale for initiating clinical development of RT-114 as a first in class oral anti-obesity therapy. Presentation: Monday, July 14, 2025

Authors

Institutions

Publication Details

Journal
Journal of the Endocrine Society
Published
2025-10-01
DOI
https://doi.org/10.1210/jendso/bvaf149.029
Primary Topic
Intramuscular injections and effects
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MON-691 Oral Delivery Of A Bispecific GLP-1/GLP-2 Receptor Agonist (PG-102) Via A Robotic Pill (RT-114) Achieves Bioequivalence To Subcutaneous Injection In Canines

Kristina Kaminskaya, Leonard C. Fung, April Toledo Vo, Arvinder K. Dhalla et al.
Journal of the Endocrine Society
Intramuscular injections and effects
article

MON-691 Oral Delivery Of A Bispecific GLP-1/GLP-2 Receptor Agonist (PG-102) Via A Robotic Pill (RT-114) Achieves Bioequivalence To Subcutaneous Injection In Canines

Kristina Kaminskaya, Leonard C. Fung, April Toledo Vo, Arvinder K. Dhalla, Jong-Gyun Kim, Sae-Won Kim, Sang-In Yang, Alyson Yamaguchi, Kwon‐Ho Song, Kyle Horlen, Jiseon Kim, Mohan Deepa, Hyo‐Jin Kim, Anvesh Dasari, Su‐Yeon Lee, Nidhi Patel, Heather Kennedy, Mir A. Hashim
article en

Abstract

Abstract Disclosure: A. Dasari: Rani Therapeutics. A. Dhalla: Rani Therapeutics. L. Fung: Rani Therapeutics. M. Hashim: Rani Therapeutics. K. Horlen: ; Rani Therapeutics. K. Kaminskaya: Rani Therapeutics. H. Kennedy: Rani Therapeutics. H. Kim: ProGen. J. Kim: ProGen. J. Kim: ProGen. S. Kim: ProGen. S. Lee: ProGen. D. Mohan: Rani Therapeutics. N. Patel: Rani Therapeutics. K. Song: ProGen. A. Toledo Vo: Rani Therapeutics. A. Yamaguchi: Rani Therapeutics. S. Yang: ProGen. PG-102 is a novel, long-acting bispecific agonist composed of GLP-1 and GLP-2 peptides fused to a central Fc domain. With a favorable safety profile, PG-102 is currently in Phase 2 trials for obesity and type 2 diabetes. As with most incretin mimetics, PG-102 requires injections which can lead to patient discomfort, reduced acceptance, and suboptimal adherence to therapy. To address this challenge, we have developed RT-114, an orally ingestible robotic pill which delivers PG-102 transenterically upon reaching the small intestine. RT-114 is being developed for the treatment of obesity. This nonclinical study was designed to compare the oral delivery of PG-102 via RT-114 with a subcutaneous (SC) injection of PG-102. Sixteen healthy canines were randomized to receive a single 12mg dose of PG-102 either via SC injection (N=6) or orally via RT-114 (N=10). Over a 14-day period, pharmacokinetics (PK; measured as serum drug concentrations by ELISA), pharmacodynamic (PD) outcomes (food intake and body weight), as well as safety, tolerability, and delivery reliability were evaluated. RT-114 was well tolerated and demonstrated high drug delivery reliability achieving systemic drug exposure in 90% (9/10) of the animals. Crucially, PK analysis showed that oral delivery via RT-114 achieved bioequivalence with SC injection, exhibiting comparable serum-drug profiles and 111% average bioavailability relative to SC. Consistent with PK findings, both delivery methods resulted in the same average peak weight loss of 6.7%. Notably, the RT-114 group exhibited less variability in weight loss response compared to the SC group, as indicated by a lower standard deviation (± 1.4% vs ± 5.4%), demonstrating consistent dosing accuracy and suggesting potentially more predictable effects with oral delivery. PK-PD correlation analysis demonstrated a clear positive association between serum PG-102 levels and reduced food intake, consistent with the drug’s expected mechanism of action. Importantly, allometric modeling indicated strong concordance between the canine SC PK data and published human SC PK data, supporting the potential translatability of these RT-114 findings to humans. In summary, this nonclinical study demonstrated that the RT-114 oral robotic pill successfully delivered the bispecific GLP-1/GLP-2 receptor agonist PG-102 to achieve both PK and PD bioequivalence to SC injection. By offering a potentially more convenient alternative to SC injections, RT-114 holds promise for improving patient acceptance and long-term adherence. Moreover, targeted intestinal delivery via RT-114 may better mimic physiologic incretin release, potentially enhancing gut-brain pathway engagement. Collectively, these compelling nonclinical results provide a robust rationale for initiating clinical development of RT-114 as a first in class oral anti-obesity therapy. Presentation: Monday, July 14, 2025

Journal of the Endocrine SocietyVol. 9(Supplement_1)
Ligand Pharmaceuticals (United Kingdom) (GB), ToolGen (South Korea) (KR), Rani Therapeutics (United States) (US)
Openalex Percentile: Top 55%
Intramuscular injections and effects
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.