Thoracic Motion Analysis Using a TrueDepth Camera in Patients with Relapsing Polychondritis: A Pilot Study

<b>Background/Objectives</b>: Relapsing polychondritis (RP) is a rare autoimmune disorder marked by recurrent inflammation of cartilaginous tissues, including the airways. Airway involvement, such as subglottic stenosis and airway malacia, significantly impacts prognosis. Although spirometry is the standard for evaluating respiratory function, it may be unfeasible in patients with severe airway narrowing or tracheostomy. This study evaluated the potential of a smartphone-based application, DepthRecorder, which uses the iPhone's TrueDepth camera to analyze thoracic motion in real time. <b>Methods</b>: Twelve patients with RP were enrolled. All underwent simultaneous respiratory assessment using spirometry and the DepthRecorder application. Thoracic motion data were corrected for height using previously validated regression formulas. Correlation between DepthRecorder and spirometry values was analyzed using Spearman's rank correlation for forced vital capacity (FVC), forced expiratory volume in one second (FEV<sub>1</sub>), and the FEV<sub>1</sub>/FVC ratio. <b>Results</b>: Mean age was 53.8 ± 13.3 years, with equal numbers of males and females. Before correction, DepthRecorder showed moderate correlations for FEV<sub>1</sub> (ρ = 0.48, <i>p</i> = 0.003) and FEV<sub>1</sub>/FVC (%) (ρ = 0.57, <i>p</i> < 0.001). After correction, stronger correlations were observed for FVC (ρ = 0.76, <i>p</i> < 0.001), FEV<sub>1</sub> (ρ = 0.72, <i>p</i> < 0.001), and FEV<sub>1</sub>/FVC (%) (ρ = 0.60, <i>p</i> < 0.001). <b>Conclusions</b>: The DepthRecorder application demonstrated strong correlations with spirometry following height-based correction. This method may offer a practical, non-invasive tool for respiratory assessment in RP patients who cannot undergo conventional lung function testing. Further studies are needed to validate these findings and establish clinical reference standards.

Authors

Institutions

Publication Details

Journal
Healthcare
Published
2025-10-22
DOI
https://doi.org/10.3390/healthcare13212664
Primary Topic
Otitis Media and Relapsing Polychondritis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thoracic Motion Analysis Using a TrueDepth Camera in Patients with Relapsing Polychondritis: A Pilot Study

Masamichi Mineshita, Hiroshi Handa, Hiroki Nishine, Takemi Matsui et al.
Healthcare
Otitis Media and Relapsing Polychondritis
article

Thoracic Motion Analysis Using a TrueDepth Camera in Patients with Relapsing Polychondritis: A Pilot Study

Masamichi Mineshita, Hiroshi Handa, Hiroki Nishine, Takemi Matsui, Yoshihiro Nishi, Shohei Sato
article en

Abstract

<b>Background/Objectives</b>: Relapsing polychondritis (RP) is a rare autoimmune disorder marked by recurrent inflammation of cartilaginous tissues, including the airways. Airway involvement, such as subglottic stenosis and airway malacia, significantly impacts prognosis. Although spirometry is the standard for evaluating respiratory function, it may be unfeasible in patients with severe airway narrowing or tracheostomy. This study evaluated the potential of a smartphone-based application, DepthRecorder, which uses the iPhone's TrueDepth camera to analyze thoracic motion in real time. <b>Methods</b>: Twelve patients with RP were enrolled. All underwent simultaneous respiratory assessment using spirometry and the DepthRecorder application. Thoracic motion data were corrected for height using previously validated regression formulas. Correlation between DepthRecorder and spirometry values was analyzed using Spearman's rank correlation for forced vital capacity (FVC), forced expiratory volume in one second (FEV<sub>1</sub>), and the FEV<sub>1</sub>/FVC ratio. <b>Results</b>: Mean age was 53.8 ± 13.3 years, with equal numbers of males and females. Before correction, DepthRecorder showed moderate correlations for FEV<sub>1</sub> (ρ = 0.48, <i>p</i> = 0.003) and FEV<sub>1</sub>/FVC (%) (ρ = 0.57, <i>p</i> < 0.001). After correction, stronger correlations were observed for FVC (ρ = 0.76, <i>p</i> < 0.001), FEV<sub>1</sub> (ρ = 0.72, <i>p</i> < 0.001), and FEV<sub>1</sub>/FVC (%) (ρ = 0.60, <i>p</i> < 0.001). <b>Conclusions</b>: The DepthRecorder application demonstrated strong correlations with spirometry following height-based correction. This method may offer a practical, non-invasive tool for respiratory assessment in RP patients who cannot undergo conventional lung function testing. Further studies are needed to validate these findings and establish clinical reference standards.

HealthcareVol. 13(21)
St. Marianna University School of Medicine (JP), Tokyo Metropolitan University (JP)
Openalex Percentile: Top 56%
Otitis Media and Relapsing Polychondritis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.