Research on DC Arc Fault Testing Technology for Photovoltaic Systems

In light of the global energy shortage, the development of renewable energy has become increasingly vital. With China’s commitment to achieving “carbon peak and carbon neutrality,” photovoltaic power generation has emerged as a focal point in new energy development. However, DC arc faults in photovoltaic systems pose significant safety hazards, potentially leading to electrical fires. While new detection technologies for DC arc faults in photovoltaic power generation systems have advanced rapidly, the diversity of international standards—such as UL 1699 B, GB/T 39750, IEC 63027, and CGC/GF 175—limits both the construction of experimental platforms and the universality of detection technologies. Current research often relies on a single standard to establish experimental platforms, resulting in detection methods with limited applicability and an inability to validate technological effectiveness fully. To address this issue, this paper conducts an in-depth study of four international and national standards (IEC 63027; UL 1699 B, GB/T 39750, and CGC/GF 175), focusing on the discrepancies in decoupling methods, impedance parameter settings, and experimental circuit topologies, including series and parallel arc scenarios. Through comprehensive comparative analysis of multiple standards, this study integrates major international and domestic specifications to develop a multi-standard compatible experimental platform. The platform is designed to accommodate diverse topologies and parameter requirements, enabling efficient collection of arc test data and performance evaluation of arc fault detection devices. It also provides a standardized foundation for the performance testing and classification of DC arc circuit breakers in photovoltaic power generation systems. Through a comprehensive multi-standard comparative analysis, we systematically analyze the technical differences in photovoltaic DC arc detection. We construct a multi-standard compatible experimental platform by integrating mainstream international and domestic standards. This platform is designed to accommodate various topological structures and parameter requirements, facilitating the collection of arcing experimental data and assessment of the performance of arc fault detection devices. The findings from this research provide both theoretical and experimental foundations for developing unified technical guidelines for photovoltaic DC arc protection. This will aid in standardizing the development of detection devices and enhancing the electrical safety of photovoltaic systems. Ultimately, this work is significant for promoting the safe utilization of new energy within the framework of the dual carbon goals. Moving forward, it is crucial to enhance the generalization abilities of detection algorithms further and foster the integration of standards and industrial applications.

Authors

Institutions

Publication Details

Journal
Processes
Published
2025-10-22
DOI
https://doi.org/10.3390/pr13113386
Citations
1
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on DC Arc Fault Testing Technology for Photovoltaic Systems

Peter He, Yao Wang, Wencong Xu, Zhenhua Xie et al.
1 citations
Processes
Electrical Fault Detection and Protection
0.73
article

Research on DC Arc Fault Testing Technology for Photovoltaic Systems

Peter He, Yao Wang, Wencong Xu, Zhenhua Xie, Zheng Wang, Renxiang Ding
article en
1 citations

Abstract

In light of the global energy shortage, the development of renewable energy has become increasingly vital. With China’s commitment to achieving “carbon peak and carbon neutrality,” photovoltaic power generation has emerged as a focal point in new energy development. However, DC arc faults in photovoltaic systems pose significant safety hazards, potentially leading to electrical fires. While new detection technologies for DC arc faults in photovoltaic power generation systems have advanced rapidly, the diversity of international standards—such as UL 1699 B, GB/T 39750, IEC 63027, and CGC/GF 175—limits both the construction of experimental platforms and the universality of detection technologies. Current research often relies on a single standard to establish experimental platforms, resulting in detection methods with limited applicability and an inability to validate technological effectiveness fully. To address this issue, this paper conducts an in-depth study of four international and national standards (IEC 63027; UL 1699 B, GB/T 39750, and CGC/GF 175), focusing on the discrepancies in decoupling methods, impedance parameter settings, and experimental circuit topologies, including series and parallel arc scenarios. Through comprehensive comparative analysis of multiple standards, this study integrates major international and domestic specifications to develop a multi-standard compatible experimental platform. The platform is designed to accommodate diverse topologies and parameter requirements, enabling efficient collection of arc test data and performance evaluation of arc fault detection devices. It also provides a standardized foundation for the performance testing and classification of DC arc circuit breakers in photovoltaic power generation systems. Through a comprehensive multi-standard comparative analysis, we systematically analyze the technical differences in photovoltaic DC arc detection. We construct a multi-standard compatible experimental platform by integrating mainstream international and domestic standards. This platform is designed to accommodate various topological structures and parameter requirements, facilitating the collection of arcing experimental data and assessment of the performance of arc fault detection devices. The findings from this research provide both theoretical and experimental foundations for developing unified technical guidelines for photovoltaic DC arc protection. This will aid in standardizing the development of detection devices and enhancing the electrical safety of photovoltaic systems. Ultimately, this work is significant for promoting the safe utilization of new energy within the framework of the dual carbon goals. Moving forward, it is crucial to enhance the generalization abilities of detection algorithms further and foster the integration of standards and industrial applications.

ProcessesVol. 13(11)
Hebei University of Technology (CN), Zhejiang Institute of Special Equipment Inspection (CN), Zhejiang Lab (CN), Zhejiang Energy Group (China) (CN)
Natural Science Foundation of Fujian Province, Natural Science Foundation of Zhejiang Province
Openalex Percentile: Top 22%
Electrical Fault Detection and Protection
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.