Direct Laser Interference Patterning (DLIP) on PEEK Coating for Biomedical and Dental Applications

Polyether ether ketone (PEEK) is widely recognized for its biocompatibility and mechanical stability, making it a promising coating material for dental implants. However, unmodified surfaces may lack optimal properties for osseointegration and antibacterial resistance. Direct laser interference patterning (DLIP) is an advanced technique for introducing controlled micro- and nanoscale surface features to enhance implant performance. This study aims to investigate the surface characteristics, antibacterial effect, and biocompatibility of DLIP-functionalized PEEK coatings electrophoretically deposited on 316L stainless steel (SS).PEEK was deposited onto 316L SS substrates via electrophoretic deposition and subsequently functionalized using DLIP to create periodic surface patterns with spatial periods of 1, 1.5, and 2 µm. The modified surfaces were characterized using scanning electron microscopy, contact angle (wettability), and surface roughness measurements. Antibacterial activity was assessed using the turbidity method against <i>Escherichia coli</i>. Biocompatibility was evaluated via MG-63 osteoblast-like cell viability analysis.The DLIP-functionalized PEEK surface with a 1.5-µm spatial period exhibited the most favorable surface features, with a contact angle of 92 ± 1° and surface roughness of 2.04 ± 0.03 µm. This configuration significantly inhibited <i>E. coli</i> growth and achieved 80% cell viability, indicating enhanced antibacterial properties and biocompatibility.DLIP is an effective technique for functionalizing PEEK coatings, improving key surface characteristics that support antibacterial activity and osteoblast cell compatibility. Among the tested configurations, a 1.5-µm spatial period yielded the most promising results.This study supports the application of DLIP-functionalized PEEK coatings for dental implants, offering a novel and translatable surface.

Authors

Institutions

Publication Details

Journal
European Journal of Dentistry
Published
2025-10-22
DOI
https://doi.org/10.1055/s-0045-1812108
Citations
1
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct Laser Interference Patterning (DLIP) on PEEK Coating for Biomedical and Dental Applications

Khalil Ahmad, Muhammad Amber Fareed
1 citations
European Journal of Dentistry
Bone Tissue Engineering Materials
0.67
article

Direct Laser Interference Patterning (DLIP) on PEEK Coating for Biomedical and Dental Applications

Khalil Ahmad, Muhammad Amber Fareed
article en
1 citations

Abstract

Polyether ether ketone (PEEK) is widely recognized for its biocompatibility and mechanical stability, making it a promising coating material for dental implants. However, unmodified surfaces may lack optimal properties for osseointegration and antibacterial resistance. Direct laser interference patterning (DLIP) is an advanced technique for introducing controlled micro- and nanoscale surface features to enhance implant performance. This study aims to investigate the surface characteristics, antibacterial effect, and biocompatibility of DLIP-functionalized PEEK coatings electrophoretically deposited on 316L stainless steel (SS).PEEK was deposited onto 316L SS substrates via electrophoretic deposition and subsequently functionalized using DLIP to create periodic surface patterns with spatial periods of 1, 1.5, and 2 µm. The modified surfaces were characterized using scanning electron microscopy, contact angle (wettability), and surface roughness measurements. Antibacterial activity was assessed using the turbidity method against <i>Escherichia coli</i>. Biocompatibility was evaluated via MG-63 osteoblast-like cell viability analysis.The DLIP-functionalized PEEK surface with a 1.5-µm spatial period exhibited the most favorable surface features, with a contact angle of 92 ± 1° and surface roughness of 2.04 ± 0.03 µm. This configuration significantly inhibited <i>E. coli</i> growth and achieved 80% cell viability, indicating enhanced antibacterial properties and biocompatibility.DLIP is an effective technique for functionalizing PEEK coatings, improving key surface characteristics that support antibacterial activity and osteoblast cell compatibility. Among the tested configurations, a 1.5-µm spatial period yielded the most promising results.This study supports the application of DLIP-functionalized PEEK coatings for dental implants, offering a novel and translatable surface.

European Journal of Dentistry
Ajman University (AE), Institute of Space Technology (PK)
Ajman University
Openalex Percentile: Top 25%
Bone Tissue Engineering Materials
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.