Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

• A novel insulated cladding composed of foamed cement and vinyl siding is reported. • The foamed cement exhibits a low thermal conductivity (0.033–0.036 W/m-K) • Cladding suits nonstructural use and, with coatings, resists moisture transport effectively. • Simulations across 50 U.S. locations shows a significant energy savings and cost. This study evaluates a novel insulated cladding composed of foamed cement and vinyl siding that is designed as a retrofit product to enhance thermal performance in U.S. residential buildings. Experimental measurements showed that foamed cement exhibits a thermal conductivity of 0.0334–0.0365 W/m-K (R-value of 4.0–4.3 °F⋅ft 2 ⋅h/BTU), which is significantly higher than that of conventional fiber cement boards. Although mechanical testing confirmed the material’s brittleness and low strength, it also indicated its suitability for nonstructural insulation applications. Water vapor permeability testing demonstrated effective moisture resistance with the polymer coating. To evaluate the insulated cladding’s energy performance, we used the U.S. Department of Energy’s prototype single-family building model and simulated across 50 locations spanning 16 International Energy Conservation Code climate zones. The R-7 (R-value of 7 °F⋅ft 2 ⋅h/BTU per inch) retrofit cladding resulted in heating energy savings up to 275 therms (Fairbanks, AK) and cooling energy savings up to 1,547 kWh (Phoenix, AZ). The energy cost savings varied by region, but the highest annual cost savings ($434/year) were observed in Santa Maria, CA, and the highest annual cost savings percentage (37 %) were noted in Monterey, CA. On a national scale, the insulated retrofit provided an average annual energy cost reduction of 16 %, highlighting the cladding system’s broad applicability and financial viability.

Authors

Institutions

Publication Details

Journal
Energy and Buildings
Published
2025-10-23
DOI
https://doi.org/10.1016/j.enbuild.2025.116590
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

Ravi Anant Kishore, Xiong Shu, Chuck Booten, Arthur J. M. Yang et al.
Energy and Buildings
Building Energy and Comfort Optimization
article

Experimental characterization and potential energy savings of insulated cladding for U.S. residential buildings

Ravi Anant Kishore, Xiong Shu, Chuck Booten, Arthur J. M. Yang, Lingfeng Lu, Sajith Wijesuriya, Zhiying Xiao, Marcus Bianchi, Ishan Niranga Jayalath
article en

Abstract

• A novel insulated cladding composed of foamed cement and vinyl siding is reported. • The foamed cement exhibits a low thermal conductivity (0.033–0.036 W/m-K) • Cladding suits nonstructural use and, with coatings, resists moisture transport effectively. • Simulations across 50 U.S. locations shows a significant energy savings and cost. This study evaluates a novel insulated cladding composed of foamed cement and vinyl siding that is designed as a retrofit product to enhance thermal performance in U.S. residential buildings. Experimental measurements showed that foamed cement exhibits a thermal conductivity of 0.0334–0.0365 W/m-K (R-value of 4.0–4.3 °F⋅ft 2 ⋅h/BTU), which is significantly higher than that of conventional fiber cement boards. Although mechanical testing confirmed the material’s brittleness and low strength, it also indicated its suitability for nonstructural insulation applications. Water vapor permeability testing demonstrated effective moisture resistance with the polymer coating. To evaluate the insulated cladding’s energy performance, we used the U.S. Department of Energy’s prototype single-family building model and simulated across 50 locations spanning 16 International Energy Conservation Code climate zones. The R-7 (R-value of 7 °F⋅ft 2 ⋅h/BTU per inch) retrofit cladding resulted in heating energy savings up to 275 therms (Fairbanks, AK) and cooling energy savings up to 1,547 kWh (Phoenix, AZ). The energy cost savings varied by region, but the highest annual cost savings ($434/year) were observed in Santa Maria, CA, and the highest annual cost savings percentage (37 %) were noted in Monterey, CA. On a national scale, the insulated retrofit provided an average annual energy cost reduction of 16 %, highlighting the cladding system’s broad applicability and financial viability.

Energy and BuildingsVol. 350
National Laboratory of the Rockies (US), Thermo Fisher Scientific (Israel) (IL)
Openalex Percentile: Top 67%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.