Optical and clinical outcomes of a new diffractive trifocal intraocular lens

PurposeTo optically characterize and clinically evaluate the new trifocal AT ELANA 841P intraocular lens (IOL).MethodsThe optical imaging performance was assessed using an on-bench model eye through the Through-Focus Modulation Transfer Function Area (TF-MTFa) from +1.00 to -3.50D. The clinical study included manifest refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, distance-corrected intermediate (DCIVA) and near visual acuity (DCNVA), binocular photopic and mesopic contrast sensitivity (CS) and binocular defocus curve. Postoperative evaluation was performed 3 months after surgery.ResultsOptimal optical quality is observed at the distance focus on the TF-MTFa curve. From there, optical quality continuously degrades, initially rapid up to approximately -0.75D, then much slower extending to -2.0D. Subsequently, optical quality improves before a decline from -2.75D. The clinical study involved 40 patients. The mean postoperative <b>monocular</b> UDVA and CDVA were <b>0.04</b> <b>±</b> <b>0.05</b> and <b>0.01</b> <b>±</b> <b>0.02</b> logMAR, respectively. <b>All eyes achieved</b> a <b>monocular</b> UDVA of <b>0.2 logMAR</b> or better and a <b>monocular</b> CDVA of <b>0.1</b> logMAR or better. All patients reached a binocular DCNVA of 0.2 logMAR or better, and 95% achieved a DCIVA of 0.2 logMAR or better. The defocus curve yielded a range from +0.50 to -2.5D, in which the mean visual acuity was 0.1 logMAR or better. The binocular distance CS was within normal limits.ConclusionsThe implantation of the new AT ELANA IOL provided a satisfactory range of visual quality from distance to near, in excellent agreement with the IOL optical performance obtained with the on-bench model eye.

Authors

Institutions

Publication Details

Journal
European Journal of Ophthalmology
Published
2025-10-22
DOI
https://doi.org/10.1177/11206721251387374
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical and clinical outcomes of a new diffractive trifocal intraocular lens

Marı́a S. Millán, Carlos Lisa, Belén Alfonso-Bartolozzi, Fidel Vega et al.
European Journal of Ophthalmology
Ophthalmology and Visual Impairment Studies
article

Optical and clinical outcomes of a new diffractive trifocal intraocular lens

Marı́a S. Millán, Carlos Lisa, Belén Alfonso-Bartolozzi, Fidel Vega, David Madrid‐Costa, José F. Alfonso, Luis Fernández-Vega-Cueto
article en

Abstract

PurposeTo optically characterize and clinically evaluate the new trifocal AT ELANA 841P intraocular lens (IOL).MethodsThe optical imaging performance was assessed using an on-bench model eye through the Through-Focus Modulation Transfer Function Area (TF-MTFa) from +1.00 to -3.50D. The clinical study included manifest refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, distance-corrected intermediate (DCIVA) and near visual acuity (DCNVA), binocular photopic and mesopic contrast sensitivity (CS) and binocular defocus curve. Postoperative evaluation was performed 3 months after surgery.ResultsOptimal optical quality is observed at the distance focus on the TF-MTFa curve. From there, optical quality continuously degrades, initially rapid up to approximately -0.75D, then much slower extending to -2.0D. Subsequently, optical quality improves before a decline from -2.75D. The clinical study involved 40 patients. The mean postoperative <b>monocular</b> UDVA and CDVA were <b>0.04</b> <b>±</b> <b>0.05</b> and <b>0.01</b> <b>±</b> <b>0.02</b> logMAR, respectively. <b>All eyes achieved</b> a <b>monocular</b> UDVA of <b>0.2 logMAR</b> or better and a <b>monocular</b> CDVA of <b>0.1</b> logMAR or better. All patients reached a binocular DCNVA of 0.2 logMAR or better, and 95% achieved a DCIVA of 0.2 logMAR or better. The defocus curve yielded a range from +0.50 to -2.5D, in which the mean visual acuity was 0.1 logMAR or better. The binocular distance CS was within normal limits.ConclusionsThe implantation of the new AT ELANA IOL provided a satisfactory range of visual quality from distance to near, in excellent agreement with the IOL optical performance obtained with the on-bench model eye.

European Journal of OphthalmologyVol. 36(2)
Universidad Complutense de Madrid (ES), Fernández-Vega Ophthalmological Institute (ES), Universitat Politècnica de Catalunya (ES)
Openalex Percentile: Top 59%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.