INTRAOPERATIVE IMAGING TO DETECT OCCULT PENETRATION OF SCREWS AFTER VOLAR PLATING OF DISTAL RADIUS FRACTURES: A CADAVERIC STUDY

Hardware prominence is one of the major established complications following volar plating of distal radius fractures. The purpose of this cadaveric study is to compare two conventional fluoroscopic imaging views (Carpal Shoot-Through [CST] and Dorsal Horizon [DH] views) with ultrasound to establish the best intra-operative imaging modality for surgeons to use to identify penetration of screws through the dorsal cortex and / or into the distal radioulnar joint. Twelve human cadaveric upper limb specimens were instrumented with distal radius variable angle locking plates and four distal locking screws from a volar approach. CST, DH views and ultrasound evaluations were compared to identify prominent screws. There were 6 surgeons divided into 3 groups of different clinical experience performing the evaluations. Sensitivity and specificity of detecting screw penetration along with the surgeon's confidence in each modality were established. CST view was the most sensitive in identifying the presence of dorsal screw penetration (100%) and absence of dorsal screw penetration (78%). DH view had the highest sensitivity in recognizing DRUJ screw penetration (89%). Ultrasound evaluation had the lowest sensitivity and specificity (28%, 56% respectively). The fellowship trained upper extremity surgeons had the highest sensitivity and specificity rate of 78% and 78% respectively. Surgeon's ability to perform as well as confidence in evaluating for screw penetration was highest with the CST view. CST view was found to be the best intra-operative imaging modality to “rule in” and “rule out” screw penetration through the dorsal cortex. DH view was most reliable in detecting DRUJ screw penetration. Clinical experience was determined to be an important factor for both dorsal cortex and DRUJ evaluation. Ultrasound evaluation had the lowest sensitivity and specificity in all categories, demonstrating that this not a reliable modality for surgeons without specific training in point-of-care ultrasonography.

Authors

Institutions

Publication Details

Journal
Orthopaedic Proceedings
Published
2025-10-22
DOI
https://doi.org/10.1302/1358-992x.2025.10.124
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

INTRAOPERATIVE IMAGING TO DETECT OCCULT PENETRATION OF SCREWS AFTER VOLAR PLATING OF DISTAL RADIUS FRACTURES: A CADAVERIC STUDY

Ryan Paul, Jonathan Persitz, Norah Matthies, Henry W. S. Schroeder et al.
Orthopaedic Proceedings
Orthopedic Surgery and Rehabilitation
article

INTRAOPERATIVE IMAGING TO DETECT OCCULT PENETRATION OF SCREWS AFTER VOLAR PLATING OF DISTAL RADIUS FRACTURES: A CADAVERIC STUDY

Ryan Paul, Jonathan Persitz, Norah Matthies, Henry W. S. Schroeder, Chae-Young Kim, A. Chan, R Shor
article en

Abstract

Hardware prominence is one of the major established complications following volar plating of distal radius fractures. The purpose of this cadaveric study is to compare two conventional fluoroscopic imaging views (Carpal Shoot-Through [CST] and Dorsal Horizon [DH] views) with ultrasound to establish the best intra-operative imaging modality for surgeons to use to identify penetration of screws through the dorsal cortex and / or into the distal radioulnar joint. Twelve human cadaveric upper limb specimens were instrumented with distal radius variable angle locking plates and four distal locking screws from a volar approach. CST, DH views and ultrasound evaluations were compared to identify prominent screws. There were 6 surgeons divided into 3 groups of different clinical experience performing the evaluations. Sensitivity and specificity of detecting screw penetration along with the surgeon's confidence in each modality were established. CST view was the most sensitive in identifying the presence of dorsal screw penetration (100%) and absence of dorsal screw penetration (78%). DH view had the highest sensitivity in recognizing DRUJ screw penetration (89%). Ultrasound evaluation had the lowest sensitivity and specificity (28%, 56% respectively). The fellowship trained upper extremity surgeons had the highest sensitivity and specificity rate of 78% and 78% respectively. Surgeon's ability to perform as well as confidence in evaluating for screw penetration was highest with the CST view. CST view was found to be the best intra-operative imaging modality to “rule in” and “rule out” screw penetration through the dorsal cortex. DH view was most reliable in detecting DRUJ screw penetration. Clinical experience was determined to be an important factor for both dorsal cortex and DRUJ evaluation. Ultrasound evaluation had the lowest sensitivity and specificity in all categories, demonstrating that this not a reliable modality for surgeons without specific training in point-of-care ultrasonography.

Orthopaedic ProceedingsVol. 107-B(SUPP_10)
University Health Network (CA), Toronto Western Hospital (CA)
Openalex Percentile: Top 53%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.