A Mechanical Rate-Controlled Electricity-Free Medication Infusion Device for Low- and Middle-Income Countries

Abstract Continuous intravenous (IV) medication delivery is an integral part of patient care due to the increased dose precision and more immediate concentration of medication in the bloodstream as compared to alternative methods. However, this standard of care is often inaccessible in low- and middle-income countries (LMICs). Based upon a clinical needs assessment conducted in the Emergency Department at a teaching hospital in Ghana, we identified a need to create a more accessible device to provide rate-controlled infusion of medication. In this paper, we discuss the development and initial preclinical testing of a mechanical, rate-controlled medication infusion device, intended for use in LMICs. The proof-of-concept prototype presented in this paper was iteratively designed, fabricated, and tested. The prototype includes mainspring, escapement, variable transmission, and lead screw subsystems that allow for rate-controlled infusion of medication without the use of electricity. We conducted initial verification testing to assess the potential for success of this proof-of-concept prototype. Our initial testing results are promising and suggest the need for continued development of the mechanical rate-controlled medication infusion device. Based on our testing results, we outline priority areas for continued device iteration and testing, along with future considerations for implementation in Ghana and in other LMICs. The design and initial testing presented in this paper demonstrate the potential for an innovative, context-appropriate medical technology to address critical healthcare delivery challenges in resource-constrained environments worldwide.

Authors

Institutions

Publication Details

Journal
Journal of Medical Devices
Published
2025-10-22
DOI
https://doi.org/10.1115/1.4070182
Primary Topic
Pharmaceutical studies and practices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Mechanical Rate-Controlled Electricity-Free Medication Infusion Device for Low- and Middle-Income Countries

Dhanalakshmi K. Thiyagarajan, Elizabeth Kappler, Emmanuel Kwasi Acheampong, Stuart J. Connolly et al.
Journal of Medical Devices
Pharmaceutical studies and practices
article

A Mechanical Rate-Controlled Electricity-Free Medication Infusion Device for Low- and Middle-Income Countries

Dhanalakshmi K. Thiyagarajan, Elizabeth Kappler, Emmanuel Kwasi Acheampong, Stuart J. Connolly, J.M. Kramer, Ethan Selle
article en

Abstract

Abstract Continuous intravenous (IV) medication delivery is an integral part of patient care due to the increased dose precision and more immediate concentration of medication in the bloodstream as compared to alternative methods. However, this standard of care is often inaccessible in low- and middle-income countries (LMICs). Based upon a clinical needs assessment conducted in the Emergency Department at a teaching hospital in Ghana, we identified a need to create a more accessible device to provide rate-controlled infusion of medication. In this paper, we discuss the development and initial preclinical testing of a mechanical, rate-controlled medication infusion device, intended for use in LMICs. The proof-of-concept prototype presented in this paper was iteratively designed, fabricated, and tested. The prototype includes mainspring, escapement, variable transmission, and lead screw subsystems that allow for rate-controlled infusion of medication without the use of electricity. We conducted initial verification testing to assess the potential for success of this proof-of-concept prototype. Our initial testing results are promising and suggest the need for continued development of the mechanical rate-controlled medication infusion device. Based on our testing results, we outline priority areas for continued device iteration and testing, along with future considerations for implementation in Ghana and in other LMICs. The design and initial testing presented in this paper demonstrate the potential for an innovative, context-appropriate medical technology to address critical healthcare delivery challenges in resource-constrained environments worldwide.

Journal of Medical DevicesVol. 20(1)
University of Michigan (US), Komfo Anokye Teaching Hospital (GH), Michigan Medicine (US)
Openalex Percentile: Top 57%
Pharmaceutical studies and practices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.