Galvanic Coupling Channel Characterization for Wearable Devices

Galvanic Coupling (GC) Intra-Body Communication offers a promising solution for reliable, low-power data transmission in wearable medical devices. However, signal performance is highly sensitive to electrode material and skin-electrode interface properties. This study uses finite element modeling (FEM) to quantify the effects of electrode design, including material choice, conductive gel, and foam layers, on the GC channel frequency response (CFR), focusing on attenuation, phase delay, and group delay. Results show that incorporating gel and foam significantly enhances signal transmission by reducing attenuation, minimizing phase distortion, and stabilizing group delay across a broad frequency range. These improvements help mitigate performance disparities between Ag/AgCl and copper (Cu) electrodes, supporting the development of high-performance, energy-efficient intra-body networks for wearable healthcare applications.

Authors

Institutions

Publication Details

Published
2025-10-22
DOI
https://doi.org/10.1145/3760544.3764132
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Galvanic Coupling Channel Characterization for Wearable Devices

Silvia Mura, Anna Vizziello, Maurizio Magarini, Pietro Savazzi et al.
Advanced Sensor and Energy Harvesting Materials
article

Galvanic Coupling Channel Characterization for Wearable Devices

Silvia Mura, Anna Vizziello, Maurizio Magarini, Pietro Savazzi, Chiara Cavigliano
article en

Abstract

Galvanic Coupling (GC) Intra-Body Communication offers a promising solution for reliable, low-power data transmission in wearable medical devices. However, signal performance is highly sensitive to electrode material and skin-electrode interface properties. This study uses finite element modeling (FEM) to quantify the effects of electrode design, including material choice, conductive gel, and foam layers, on the GC channel frequency response (CFR), focusing on attenuation, phase delay, and group delay. Results show that incorporating gel and foam significantly enhances signal transmission by reducing attenuation, minimizing phase distortion, and stabilizing group delay across a broad frequency range. These improvements help mitigate performance disparities between Ag/AgCl and copper (Cu) electrodes, supporting the development of high-performance, energy-efficient intra-body networks for wearable healthcare applications.

University of Pavia (IT), Politecnico di Milano (IT)
European Commission
Openalex Percentile: Top 71%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Galvanic Coupling Channel Characterization for Wearable Devices — Silvia Mura, Anna Vizziello, et al. · (2025) | TGRS Research Map | TGRS