DEVELOPMENT AND PRELIMINARY CLINICAL EVALUATION OF A NOVEL MEDIAL HIGH TIBIAL OSTEOTOMY WEDGE FIXATION SYSTEM FOR KNEE OSTEOARTHRITIS

To address the challenges of insufficient support and fixation and unstable limb alignment correction after high tibial osteotomy (HTO), a novel medial high tibial osteotomy wedge fixation system was developed. This study evaluates its mechanical performance, biocompatibility, and preliminary clinical outcomes in patients with knee osteoarthritis (OA). Design and Manufacturing. A wedge-shaped porous metal implant tailored to the medial tibial anatomy was designed and manufactured using 3D printing technology. The implant was made from porous tantalum metal with a high porosity (>75%) and optimal pore size (400–800 μm) to promote bone ingrowth and enhance fixation strength. Mechanical optimization ensured effective stress distribution and stable support. Mechanical Performance Testing. Compression, shear strength, and fatigue tests were conducted to evaluate the implant's stability and durability under dynamic loading conditions. Clinical Study. Ten patients with knee OA underwent HTO using the novel wedge fixation system. Preoperative and postoperative knee function scores (KOOS scores) were recorded, limb alignment was assessed radiographically, and complications were monitored during follow-up. Mechanical tests demonstrated that the implant provided excellent support and fatigue strength under physiological loads, maintaining stable limb alignment over time. Clinical outcomes showed that postoperative KOOS scores significantly improved from a preoperative average of 62 to 93 (12-month follow-up). Radiographic evaluation confirmed effective correction of lower limb alignment from an average 10° varus to a normal range. No implant loosening, migration, or related complications were observed during follow-up. Patients achieved satisfactory recovery with no significant pain or mobility restrictions, and bone ingrowth into the implant was observed. Conclusion. The novel medial HTO wedge fixation system demonstrates excellent mechanical properties and biocompatibility. It effectively fills the osteotomy gap, supports and fixes the tibia, and corrects lower limb alignment. Preliminary clinical results validate its safety and efficacy, offering an innovative solution for treating knee osteoarthritis.

Authors

Institutions

Publication Details

Journal
Orthopaedic Proceedings
Published
2025-10-22
DOI
https://doi.org/10.1302/1358-992x.2025.9.005
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DEVELOPMENT AND PRELIMINARY CLINICAL EVALUATION OF A NOVEL MEDIAL HIGH TIBIAL OSTEOTOMY WEDGE FIXATION SYSTEM FOR KNEE OSTEOARTHRITIS

Dewei Zhao, Liang Cheng C
Orthopaedic Proceedings
Total Knee Arthroplasty Outcomes
article

DEVELOPMENT AND PRELIMINARY CLINICAL EVALUATION OF A NOVEL MEDIAL HIGH TIBIAL OSTEOTOMY WEDGE FIXATION SYSTEM FOR KNEE OSTEOARTHRITIS

Dewei Zhao, Liang Cheng C
article en

Abstract

To address the challenges of insufficient support and fixation and unstable limb alignment correction after high tibial osteotomy (HTO), a novel medial high tibial osteotomy wedge fixation system was developed. This study evaluates its mechanical performance, biocompatibility, and preliminary clinical outcomes in patients with knee osteoarthritis (OA). Design and Manufacturing. A wedge-shaped porous metal implant tailored to the medial tibial anatomy was designed and manufactured using 3D printing technology. The implant was made from porous tantalum metal with a high porosity (>75%) and optimal pore size (400–800 μm) to promote bone ingrowth and enhance fixation strength. Mechanical optimization ensured effective stress distribution and stable support. Mechanical Performance Testing. Compression, shear strength, and fatigue tests were conducted to evaluate the implant's stability and durability under dynamic loading conditions. Clinical Study. Ten patients with knee OA underwent HTO using the novel wedge fixation system. Preoperative and postoperative knee function scores (KOOS scores) were recorded, limb alignment was assessed radiographically, and complications were monitored during follow-up. Mechanical tests demonstrated that the implant provided excellent support and fatigue strength under physiological loads, maintaining stable limb alignment over time. Clinical outcomes showed that postoperative KOOS scores significantly improved from a preoperative average of 62 to 93 (12-month follow-up). Radiographic evaluation confirmed effective correction of lower limb alignment from an average 10° varus to a normal range. No implant loosening, migration, or related complications were observed during follow-up. Patients achieved satisfactory recovery with no significant pain or mobility restrictions, and bone ingrowth into the implant was observed. Conclusion. The novel medial HTO wedge fixation system demonstrates excellent mechanical properties and biocompatibility. It effectively fills the osteotomy gap, supports and fixes the tibia, and corrects lower limb alignment. Preliminary clinical results validate its safety and efficacy, offering an innovative solution for treating knee osteoarthritis.

Orthopaedic ProceedingsVol. 107-B(SUPP_9)
Affiliated Zhongshan Hospital of Dalian University (CN)
Openalex Percentile: Top 53%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.